Technical data: |
high pressure infrared drying length
total: 4110 mm work width max. 1350 mm broad total: 1690 mm height
i.L.: 100 mm of number of lamps: 4 ea.. Lamp connection worth: 10.4 KW
of spec achievement: 80 W/cm lamp entire connected load: 41.6 KW of
exhaust air rate: 1500 + 3600 m /h exhaust air fan: 0,12 + 1.85 KW
supply air fan: 1.85 KW total connection worth: 45.42 KW of operating
side: on the left of lacquer finish: Ral 1015 the UV channel is
suitable for hardening rolls -, putty or casting orders, which
contains photo-technical Sensibilatoren as activators. As radiation
sources serve high pressure TLA dung lamps, which are
hoehenverstellbar during the enterprise individually from the outside.
Over the UV lamps highly polished reflectors are arranged which the
radiation in a precalculated angle on the workpiece surfaces steer. The UV lamps are attached with special high voltage plugs and can for
maintenance after both sides out of the channel be pulled. The UV
channel is generally isolated. With a special keys can be opened the
side panels for inspection fast. The cooling air for the workpieces is
sucked in across a from the outside controllable filter and led by
individually adjustable slot nozzles directly vertically on the
workpiece surfaces. For the UV lamps the cooling air is led past in
such a way the quartz tube that an all-round, optimal operating
temperature is obtained. And the exhaust in the UV channel are
obligation-led. The UV lamps are optically controllable during the
enterprise. With transportation stop UV lamps are autormatisch dipped
the headlights. For the control, monitoring and power supply the
channel is attached to the UV switchgear cabinet KTR 607. Note: max. Workpiece strength 80 mm of special equipment: without intake screen
and sliding hood channel turned installs inclusively. Ventilating zone
length 1900 mm at the intake
The data are mechanically translated in the english language. Translation errors are possible. No guarantee for printed data and pricing.
|
|