Warming cupboard, Memmert, BE 600, , Warming cupboard of Memmert, on roles, F-NR 840,098, 220V, 2000W, DIN 1288-Kl 03.1 NennT 70 C, enclosure DIN 40050-IP20, 1115x755x1600 with table, inside 2 glass doors 1000x605x1600mm. AD-ID: A232395 More Infos click here
Point of usage baseplate --Stickstoff, MESSER SPECTRON, EM 60-1 / EM 61, , Typ EM 60-1 kind. No. 718,32072 with stop valve from brass and pressure control valve EM 61 - 10 bar of kind. No. 717.05920 AD-ID: A249342 More Infos click here
Point of usage baseplate --Wasserstoff, MESSER SPECTRON, EM 60-1 / EM 61, , Typ EM 60-1 kind. No. 718,32072 with stop valve from brass and pressure control valve EM 61 - 10 bar of kind. No. 717.05920 AD-ID: A249345 More Infos click here
industry freezer, Kottermann, , , until -80 C, unfortunately is the 2.Stufe defectively, from there only to -38 C, inside bxtxh 550x500x1140, gas must are filled to deliver favorably AD-ID: A233738 More Infos click here
Large laboratory shaker with cooling/heating , , , , without any description or accessories, name plate missing; outdoor mass approximately 123 x 70 x 67 cm; utility about 56 x 68 x 40 cm, Schüttelkorb usable height from about 30 cm; Freqünz adjustable to ca . 178 / min (see photo); heating and cooling capacity in the test were not fully exhausted; examination expired; With the purchase to avoid any further demands, such as workload on functional testing, possibly repair costs, etc. [...Technical data truncated] AD-ID: A413760 More Infos click here
Point of usage baseplate -- Kohlenmonoxid, Messer Spectron, EE 60-1 / EE 61, , Typ EE 60-1 kind. No. 718,32190 with stop valve from high-grade steel and pressure control valve EE 61 - 40/10 bar of kind. No. 717.06426 AD-ID: A249306 More Infos click here
Laboratory - departure mechanism, , Astecair 3000, , Mass approx. 64 x 55 x 42 cm; 4 pieces available; indicated price is valid for whole post, sale also separately AD-ID: A259467 More Infos click here
Workbench , Rieber, , , Sterilisation workbench of fuer Endoskopie, with 3 rinses and 3 Unterschraenken with Klapptueren, 3950x700x950, 3x basin 600x400x230 AD-ID: A406291 More Infos click here
Point of usage baseplate, Messer Spectron, EM 60-1, , type EM 60-1 kind. No. 718,32072 with stop valve from brass and pressure control valve EM 61 - 10 bar of kind. No. 717.05920 AD-ID: A272169 More Infos click here
Entnahmestelen baseplate -- Methane, Messer Spectron, EM 601-1, , type EM 60-1 kind. No. 718,32072 with stop valve from brass and pressure control valve EM 61 - 10 bar of kind. No. 717.05920 AD-ID: A272187 More Infos click here
Large High speed cooling centrifuge , Sorvall Instruments, RC-5C, , As the existing documents the previous model RC-5B Plus, information concerning technical data limited. 220 V / W 4360, max. 30 A (heating would only be achieved as a result of the very gentle Anlaufes without heating significantly lower power consumption), with-out HS-4 (vessel diameter 40 cm); mass approximately 76 x 80 x 92 cm (without BxTXH panel); weight around 300 kg, probably because of the inappropriate Be [...Technical data truncated] AD-ID: A410901 More Infos click here
xyz sampler magnetic stirrer + , SENTECH - Zastro Zellweger Analytics - VARIOMAG, P/N 4923 - Multipoint HP60, , Electronic mixer with 60 points, or oscillating turning selectable. without any description, software or other accessories, so also does not function tested (according to the last operational user, one could only conclude that the magnetic stirrer seems ok). with the usual signs of wear AD-ID: A461432 More Infos click here
Darkroom box for gel documentation , INTAS, , , mass about 70 x 65 x 45 cm (WxHxD); metal, sliding plate; Weiss incident light inside; outlet and switch and extract for UV-box; Schiebbare camera shot for UV-boxes with 2 wavelengths ; Very good condition AD-ID: A413910 More Infos click here
Laboratory centrifuge , Ortho Diagnostic Systems GmbH, Suwamat 3, , 230 V/220 W; Number of revolutions does not
admit; with decaying rotor, without rotor cups; external cooling and
flushing; without operating instructions, therefore no function test
possible; Equipment was acquired as functional; Examination run off 2
devices available; Price applies per piece AD-ID: A432526 More Infos click here