2004 kW Jenbacher JMS 612 GS-N.L Cogeneration PlantJENBACHER
JMS 612 GS-N.L.
2004 kW Jenbacher JMS 612 GS-N.L Cogeneration Plant
JENBACHER
JMS 612 GS-N.L.
Condition
Used
Location
Portugal 

Show images
Show map
Machine data
- Machine type:
- 2004 kW Jenbacher JMS 612 GS-N.L Cogeneration Plant
- Manufacturer:
- JENBACHER
- Model:
- JMS 612 GS-N.L.
- Condition:
- used
Price & Location
- Location:
- Portugal

Call
Details about the offer
- Listing ID:
- A19886270
- Reference number:
- RG1040
- Update:
- 24.09.2025
Description
Used Jenbacher JMS 612 GS-N.L Gas-Powered CHP Plant
Bdedpfew T Rg Tjx Agcek
Manufactured in 2011, this combined heat and power (CHP) plant is currently configured for tri-generation — producing cooling, heating, and power within a single integrated process. Cooling is achieved via absorption chillers.
Technical Specifications:
Electrical output: 2,004 kWel
Thermal output: 4,551 kWt
Fuel consumption: 479 Nm³/h of natural gas
Gas flow rate: 2.79 kg/s
Exhaust gas temperature: 410 °C
Engine speed: 1,500 rpm
Inlet air temperature: Ambient +10 °C
Frequency: 50 Hz
Voltage: 6,300 V
Included Equipment:
Heat Recovery Boiler — Water tube design; gas flow 2.79 kg/s; inlet temperature 410 °C; outlet temperature 120 °C; water outlet 101 °C; water inlet 90 °C; recovery capacity 953 kWt.
Absorption Chiller — Refrigeration capacity 1,000 kWt; hot water flow 78.5 m³/h.
Plate Heat Exchanger — Constructed from 316 stainless steel; designed for producing hot process water using hot water recovered from the boiler.
Air Cooler — Ensures stable engine operation and optimized thermal efficiency.
Cooling Tower — Supports effective heat dissipation for continuous tri-generation performance.
More technical details, drawings, and operational data are available upon request.
Bdedpfew T Rg Tjx Agcek
Manufactured in 2011, this combined heat and power (CHP) plant is currently configured for tri-generation — producing cooling, heating, and power within a single integrated process. Cooling is achieved via absorption chillers.
Technical Specifications:
Electrical output: 2,004 kWel
Thermal output: 4,551 kWt
Fuel consumption: 479 Nm³/h of natural gas
Gas flow rate: 2.79 kg/s
Exhaust gas temperature: 410 °C
Engine speed: 1,500 rpm
Inlet air temperature: Ambient +10 °C
Frequency: 50 Hz
Voltage: 6,300 V
Included Equipment:
Heat Recovery Boiler — Water tube design; gas flow 2.79 kg/s; inlet temperature 410 °C; outlet temperature 120 °C; water outlet 101 °C; water inlet 90 °C; recovery capacity 953 kWt.
Absorption Chiller — Refrigeration capacity 1,000 kWt; hot water flow 78.5 m³/h.
Plate Heat Exchanger — Constructed from 316 stainless steel; designed for producing hot process water using hot water recovered from the boiler.
Air Cooler — Ensures stable engine operation and optimized thermal efficiency.
Cooling Tower — Supports effective heat dissipation for continuous tri-generation performance.
More technical details, drawings, and operational data are available upon request.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2020
Send inquiry
Telephone & Fax
+44 1325 ... show
These listings may also fit your interest.
Listing
Newton Aycliffe
6,983 km
1025 kW, 50Hz Caterpillar 3516 Generator Sets
CATERPILLAR3516 STD
CATERPILLAR3516 STD
Listing
Odžak
8,755 km
Gas generator
MTU20V4000 GS
MTU20V4000 GS
Listing
Sonsbeck
7,606 km
Combined heat and power plant
G2MWM
G2MWM
Listing
Balaguer
7,846 km
Welding equipment
FRONIUSMagicWave 3000
FRONIUSMagicWave 3000
Listing
Berlin
7,943 km
Combined Heat and Power Plant
HERFORD/ MARELLI
HERFORD/ MARELLI
Listing
Bruckmühl
8,172 km
Combined heat and power plant
JenbacherJGC 312 GS-N.LC
JenbacherJGC 312 GS-N.LC
Listing
Germany
10,526 km
Welding Unit
KEMPPIPS 3500
KEMPPIPS 3500
Listing
Sheffield
7,050 km
CNC Turning Centre - Horizontal
Takisawa TaiwanEX308
Takisawa TaiwanEX308
Listing
Madrid
7,603 km
Truck weighing scale
Leon
Leon
Listing
Oranienburg
7,920 km
Combined heat and power plant
LiebherrTBG 926 AGR
LiebherrTBG 926 AGR
Your listing has been deleted successfully
An error has occurred