Temperature test chamberCTS
TSR-30/1000
Temperature test chamber
CTS
TSR-30/1000
Condition
Used
Location
Borken 

Machine data
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A22185327
- Reference number:
- 23988
- Update:
- 23.06.2026
Description
CTS
Type: TSR-30/1000
Water-cooled
The type designation of the CTS cabinet series is structured as follows:
e.g., Type TSR-30/1000
1) T means: Temperature
2) S means: Stress Screening
3) R means: External Conditioning
4) -30 means: Lower temperature -30 °C
5) 1000 means: 1000 liters test chamber volume
Technical performance data:
A) TSR-30/1000 base unit without hose connections,
i.e., for use as a stand-alone temperature test chamber
Temperature tests:
Temperature range -40°C to +180°C
Final temperature -45°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 6.0 K/min
Cooling 5.0 K/min
Heat radiation
approx. 5000 W at +20°C
approx. 4200 W at ±0°C
approx. 3000 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test specimen, without radiation, and without additional equipment.
Air volume flow rate
approx. 2000 m³/h
B) TSR-30/1000 base unit with hose connections,
for connection to an on-site external test chamber
Temperature tests:
Temperature range -30°C to +170°C
Temperature deviation ≤ ±0.1 to 0.5 K over time
Average temperature change rate,
measured with the circuit short-circuited
Heating 4.0 K/min
Cooling 4.0 K/min
in the range of +150°C to -10°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test specimen, without radiation, and without additional equipment,
measured with the circuit short-circuited
Caution: The on-site external test chamber must be absolutely sealed and appropriately insulated;
any penetrations must be optimally sealed on-site.
Dimensions:
Test volume 1000 liters
Air circulation connection Ø 200 mm
Test chamber dimensions height 900 mm width 1000 mm depth 1100 mm
External dimensions height 1950 mm width 1270 mm depth 2245 mm
Technical design:
Refrigeration unit:
water-cooled, low-noise, hermetically sealed
stepless power adjustment by
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door stop on the left,
one-hand operation, lockable.
Insert grid:
stainless steel, support area 970 x 980mm
Load per grid max. 35 kg
Total load with max. grid capacity 100 kg
Test chamber lighting: Halogen lamp 20 W, 12 V
Control:
- 32-bit controller
- LCD control panel
Lhjdpjzgbntjfx Abneh
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 13.3 kW
Protection class IP 22
Sound pressure level < 60 dB(A)
Weight approx. 850 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
The listing was translated automatically. Translation errors are possible.
Type: TSR-30/1000
Water-cooled
The type designation of the CTS cabinet series is structured as follows:
e.g., Type TSR-30/1000
1) T means: Temperature
2) S means: Stress Screening
3) R means: External Conditioning
4) -30 means: Lower temperature -30 °C
5) 1000 means: 1000 liters test chamber volume
Technical performance data:
A) TSR-30/1000 base unit without hose connections,
i.e., for use as a stand-alone temperature test chamber
Temperature tests:
Temperature range -40°C to +180°C
Final temperature -45°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 6.0 K/min
Cooling 5.0 K/min
Heat radiation
approx. 5000 W at +20°C
approx. 4200 W at ±0°C
approx. 3000 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test specimen, without radiation, and without additional equipment.
Air volume flow rate
approx. 2000 m³/h
B) TSR-30/1000 base unit with hose connections,
for connection to an on-site external test chamber
Temperature tests:
Temperature range -30°C to +170°C
Temperature deviation ≤ ±0.1 to 0.5 K over time
Average temperature change rate,
measured with the circuit short-circuited
Heating 4.0 K/min
Cooling 4.0 K/min
in the range of +150°C to -10°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test specimen, without radiation, and without additional equipment,
measured with the circuit short-circuited
Caution: The on-site external test chamber must be absolutely sealed and appropriately insulated;
any penetrations must be optimally sealed on-site.
Dimensions:
Test volume 1000 liters
Air circulation connection Ø 200 mm
Test chamber dimensions height 900 mm width 1000 mm depth 1100 mm
External dimensions height 1950 mm width 1270 mm depth 2245 mm
Technical design:
Refrigeration unit:
water-cooled, low-noise, hermetically sealed
stepless power adjustment by
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door stop on the left,
one-hand operation, lockable.
Insert grid:
stainless steel, support area 970 x 980mm
Load per grid max. 35 kg
Total load with max. grid capacity 100 kg
Test chamber lighting: Halogen lamp 20 W, 12 V
Control:
- 32-bit controller
- LCD control panel
Lhjdpjzgbntjfx Abneh
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 13.3 kW
Protection class IP 22
Sound pressure level < 60 dB(A)
Weight approx. 850 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
Your listing has been deleted successfully
An error has occurred