Climatic test chamberFeutron
3702/06
Climatic test chamber
Feutron
3702/06
Condition
Used
Location
Borken 

Machine data
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A22148202
- Reference number:
- 23444
- Update:
- 18.06.2026
Description
Feutron
Type: 3702/06
Water-cooled climate test chamber
Technical data:
Nominal volume of test chamber: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Door: double-leaf, clear opening width 2000 mm, height 1000 mm
Viewing window, heated, 2 pieces, width 500 mm, height 600 mm
Feed-through opening, 1 piece, left side wall, diameter 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Temperature difference, time-dependent ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 % RH
Humidity difference, time-dependent ≤ ± 3.0 % RH
Dew point range, intermittently up to -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and dryer refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Kedpfx Aezd Sdmsbvsdn
Electrical connection: 400V 3/N/PE.AC, 50Hz
Power plug: CEE 5-pin, 32 A, with 5.0 m cable
Max. simultaneous power requirement: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: 3702/06
Water-cooled climate test chamber
Technical data:
Nominal volume of test chamber: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Door: double-leaf, clear opening width 2000 mm, height 1000 mm
Viewing window, heated, 2 pieces, width 500 mm, height 600 mm
Feed-through opening, 1 piece, left side wall, diameter 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Temperature difference, time-dependent ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 % RH
Humidity difference, time-dependent ≤ ± 3.0 % RH
Dew point range, intermittently up to -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and dryer refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Kedpfx Aezd Sdmsbvsdn
Electrical connection: 400V 3/N/PE.AC, 50Hz
Power plug: CEE 5-pin, 32 A, with 5.0 m cable
Max. simultaneous power requirement: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
Your listing has been deleted successfully
An error has occurred

















