Malvern Omnisec CHR600 + CHR7100 Resolve & Reveal GPC/SEC SystemMalvern Omnisec
CHR600 + CHR7100
Malvern Omnisec CHR600 + CHR7100 Resolve & Reveal GPC/SEC System
Malvern Omnisec
CHR600 + CHR7100
Condition
Used
Location
Duxford 

Show images
Show map
Machine data
Price & Location
- Location:
- Duxford, UK

Call
Details about the offer
- Listing ID:
- A21043862
- Reference number:
- 1525.2A
- Update:
- 22.01.2026
Description
This listing is for the Malvern CHR6000 + CHR7100 OMNISEC RESOLVE and REVEAL GPC/SEC
These units are in full working condition and ready for immediate use
What the System Measures
The combined OMNISEC RESOLVE and REVEAL GPC/SEC System provides absolute molecular weight, intrinsic viscosity, concentration, and conformational data in a single run. This eliminates the need for calibration standards, improving accuracy and confidence in results.
OMNISEC RESOLVE – The Chromatography Module
OMNISEC RESOLVE integrates four key components into a single unit:
Pump: Delivers a flow rate range of 0.01–10 mL/min with low pulsation (0.15% at 1 mL/min in water), ensuring stable baseline signals.
Degasser: Features a low-volume (960 µL) design for rapid solvent exchange, enhancing system productivity.
Autosampler: Accommodates up to 192 samples, with temperature control from 4°C to 60°C, suitable for both vials and 96-well microtiter plates.
Column Oven: Controls temperatures up to 65°C, supporting up to six analytical columns for optimal separation conditions.
Nwjdpfx Aksychy Aocjf
This integrated design minimizes baseline noise and enhances measurement sensitivity, particularly for low-concentration or low-molecular-weight samples.
OMNISEC REVEAL – The Detector Module
OMNISEC REVEAL is an advanced, fully integrated, temperature-controlled multi-detector module that includes:
Refractive Index (RI) Detector: Highly sensitive and stable, enabling accurate concentration measurement, even for low-concentration samples.
UV/Vis Photodiode Array (UV-PDA) Detector: Measures absorbance at any wavelength from 190 to 900 nm, providing versatile detection options.
Light Scattering Detectors (LALS & RALS): Deliver market-leading sensitivity, allowing measurement of molecular weights as low as 200 g/mol and injection masses as low as 100 ng, for highly reliable results.
Viscometer: Features automated balancing for precise intrinsic viscosity measurements, with a user-exchangeable capillary bridge to minimize maintenance.
The fully temperature-controlled design improves detector stability and overall sample characterization, ensuring optimal performance for sensitive applications.
OMNISEC Software
The OMNISEC software suite provides:
Unified instrument control, data acquisition, and analysis.
Calculations for molecular weight (Mn, Mw, Mz), polydispersity, radius of gyration (Rg), intrinsic viscosity, and Mark-Houwink parameters.
Support for automated, unattended operation to streamline workflows.
Key Advantages
Exceptional Sensitivity: Measures molecular weights down to 200 g/mol and injection masses as low as 100 ng.
Broad Wavelength UV/Vis Detection: Enables absorbance measurements across 190–900 nm.
Superior Stability: Temperature-controlled detectors ensure consistent, high-quality results.
Versatility: Ideal for polymers, polysaccharides, and proteins, with multi-detection SEC offering unmatched characterization detail.
Integrated Design: Reduced inter-detector volume improves peak resolution and data quality.
Accurate Viscosity Measurement: With automated viscometer balancing, ensuring reproducibility.
These units are in full working condition and ready for immediate use
What the System Measures
The combined OMNISEC RESOLVE and REVEAL GPC/SEC System provides absolute molecular weight, intrinsic viscosity, concentration, and conformational data in a single run. This eliminates the need for calibration standards, improving accuracy and confidence in results.
OMNISEC RESOLVE – The Chromatography Module
OMNISEC RESOLVE integrates four key components into a single unit:
Pump: Delivers a flow rate range of 0.01–10 mL/min with low pulsation (0.15% at 1 mL/min in water), ensuring stable baseline signals.
Degasser: Features a low-volume (960 µL) design for rapid solvent exchange, enhancing system productivity.
Autosampler: Accommodates up to 192 samples, with temperature control from 4°C to 60°C, suitable for both vials and 96-well microtiter plates.
Column Oven: Controls temperatures up to 65°C, supporting up to six analytical columns for optimal separation conditions.
Nwjdpfx Aksychy Aocjf
This integrated design minimizes baseline noise and enhances measurement sensitivity, particularly for low-concentration or low-molecular-weight samples.
OMNISEC REVEAL – The Detector Module
OMNISEC REVEAL is an advanced, fully integrated, temperature-controlled multi-detector module that includes:
Refractive Index (RI) Detector: Highly sensitive and stable, enabling accurate concentration measurement, even for low-concentration samples.
UV/Vis Photodiode Array (UV-PDA) Detector: Measures absorbance at any wavelength from 190 to 900 nm, providing versatile detection options.
Light Scattering Detectors (LALS & RALS): Deliver market-leading sensitivity, allowing measurement of molecular weights as low as 200 g/mol and injection masses as low as 100 ng, for highly reliable results.
Viscometer: Features automated balancing for precise intrinsic viscosity measurements, with a user-exchangeable capillary bridge to minimize maintenance.
The fully temperature-controlled design improves detector stability and overall sample characterization, ensuring optimal performance for sensitive applications.
OMNISEC Software
The OMNISEC software suite provides:
Unified instrument control, data acquisition, and analysis.
Calculations for molecular weight (Mn, Mw, Mz), polydispersity, radius of gyration (Rg), intrinsic viscosity, and Mark-Houwink parameters.
Support for automated, unattended operation to streamline workflows.
Key Advantages
Exceptional Sensitivity: Measures molecular weights down to 200 g/mol and injection masses as low as 100 ng.
Broad Wavelength UV/Vis Detection: Enables absorbance measurements across 190–900 nm.
Superior Stability: Temperature-controlled detectors ensure consistent, high-quality results.
Versatility: Ideal for polymers, polysaccharides, and proteins, with multi-detection SEC offering unmatched characterization detail.
Integrated Design: Reduced inter-detector volume improves peak resolution and data quality.
Accurate Viscosity Measurement: With automated viscometer balancing, ensuring reproducibility.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2019
766 listings online
Send inquiry
Telephone & Fax
+44 20 38... show
These listings may also fit your interest.
Listing
Germany
7,870 km
Spectrophotometer
Datacolor800
Datacolor800
Listing
Soerendonk
7,581 km
Eddy Current Separator
SteinertNES 100 220 E 5009
SteinertNES 100 220 E 5009
Listing
Bischofszell
8,038 km
SPECTRAL PHOTOMETER
GRETAG MACBETHEFI ES 1000 (eye-one UVcut)
GRETAG MACBETHEFI ES 1000 (eye-one UVcut)
Listing
Hadımköy
9,700 km
ULTRASONIK CLEANING MACHINES
INTERSONIKMINISONIC SERIES
INTERSONIKMINISONIC SERIES
Listing
Soerendonk
7,581 km
Eddy Current Separator
Bakker Magnetics29.723/12
Bakker Magnetics29.723/12
Listing
Budapest
8,626 km
Big Back Sack Halter system
nicht bekanntBIG BAG Sack Halter System
nicht bekanntBIG BAG Sack Halter System
Listing
Wekerom
7,540 km
Big bag filling and discharging system with dump hopper
Listing
Wekerom
7,540 km
Big bag unloading station
Listing
Germany
7,870 km
Color Sorting System
CimbriaN7-D-D
CimbriaN7-D-D
Listing
Töltéstava
8,528 km
Fume hood
BioquellAstec Monair BFC5-002
BioquellAstec Monair BFC5-002
Your listing has been deleted successfully
An error has occurred
















































































