Description
Scholz Hot Air Autoclave
SCHOLZ Hot Air Autoclave – modernized in 2019 – Working autoclave with quick-release closure
Description:
For sale is a SCHOLZ hot air autoclave that underwent extensive modernization between 2019 and 2024. The system is designed for the thermal treatment of materials under overpressure conditions and offers reliable and precise process control thanks to modern control technology and proven SCHOLZ construction.
Modernizations carried out:
In 2019:
- Installation of a new STANGE 604 program controller including control software and data logging
- Integration of a new Siemens SIMATIC S7-1500 controller (TIA Portal)
- New thermocouple feedthroughs for 12 component temperature sensors, type K
- Installation of new thermocouple panels for connecting thermocouples inside the autoclave
- New thermocouple feedthroughs for 12 additional sensors for TUS measurement, including terminal panels inside and outside the autoclave
In 2023:
- Replacement of several control valves for compressed air and cooling water control
In 2024:
- Installation of a new rotary vane vacuum pump
Modernized, well-maintained condition
Status: Final version, revision dated 11.09.2019
Technical Data:
Hot Air Autoclave System UNI Magdeburg
General Information:
- Designation: Hot Air Autoclave System
- Outer diameter: 1,350 mm
- Cylindrical length: 2,300 mm
- Loading length: 1,500 mm
Dimensions & Weight:
- Autoclave L × W × H: 4,000 × 2,200 × 2,200 mm
- Autoclave weight: 4,800 kg
- Control cabinet L × W × H: 2,400 × 600 × 2,100 mm, weight: 1,200 kg
- Silencer L × Ø: 1,300 mm × Ø 168.3 mm, weight: 40 kg
Dkedpoxrt Shofx Ah Uow
- Total system weight: approx. 6,000 kg
Electrical Data:
- Operating voltage: 400 V AC ±10%, 50 Hz ±1 Hz
- Control voltage: 230 V AC / 24 V DC
- Power consumption: approx. 68 kW
- Current consumption: approx. 120 A
Pneumatic Data:
- Control air for regulation: 8–10 bar
- Max. pressure at autoclave air inlet: 35 bar (before regulating valve group)
- Max. dust/particle size: ≤ 3 µm
Cooling Water:
- Cooling water pressure: 2–6 bar
- Cooling water consumption: 8.0 m³/h
Performance / Autoclave operation:
- Temperature range: 0–400 °C
- Max. operating pressure: 20 bar
- Test overpressure: 26 bar
Loading weight:
- Steel racks & carts: max. 60 kg
- Composite: approx. 20 kg
- Max. temperature increase (20 → 400 °C): 5 °C/min (approx. 76 min)
- Max. temperature decrease (400 → 60 °C): 5 °C/min (approx. 68 min)
Environment & Emissions:
- Operating temperature range: +5 to +40 °C
- Max. relative humidity: 90 %
- Max. altitude above sea level: 1,000 m
- Autoclave noise emission (1 m distance): ≤ 60 dB(A)
- Piping system noise emission: ≤ 80 dB(A)
- Short-term noise emission of air duct (1 m distance): ≤ 120 dB(A)
- Autoclave: 4,800 kg
- Control cabinet: 1,200 kg
- Silencer: 40 kg
- Total weight ≈ 6,040 kg (~6 tons)
Scope of Delivery:
- Hot air autoclave including quick-release closure
- Heating and cooling system
- Air and cooling water distributor
- Piping and cabling
Note:
Missing technical data (e.g., dimensions, weight, performance details) will be provided later. Buyer is responsible for installation and operation.
Contact:
For inquiries or further questions regarding the system, feel free to contact us. A viewing can be arranged by appointment.
(Changes and errors in technical data and details excepted!)
The listing was translated automatically. Translation errors are possible.
SCHOLZ Hot Air Autoclave – modernized in 2019 – Working autoclave with quick-release closure
Description:
For sale is a SCHOLZ hot air autoclave that underwent extensive modernization between 2019 and 2024. The system is designed for the thermal treatment of materials under overpressure conditions and offers reliable and precise process control thanks to modern control technology and proven SCHOLZ construction.
Modernizations carried out:
In 2019:
- Installation of a new STANGE 604 program controller including control software and data logging
- Integration of a new Siemens SIMATIC S7-1500 controller (TIA Portal)
- New thermocouple feedthroughs for 12 component temperature sensors, type K
- Installation of new thermocouple panels for connecting thermocouples inside the autoclave
- New thermocouple feedthroughs for 12 additional sensors for TUS measurement, including terminal panels inside and outside the autoclave
In 2023:
- Replacement of several control valves for compressed air and cooling water control
In 2024:
- Installation of a new rotary vane vacuum pump
Modernized, well-maintained condition
Status: Final version, revision dated 11.09.2019
Technical Data:
Hot Air Autoclave System UNI Magdeburg
General Information:
- Designation: Hot Air Autoclave System
- Outer diameter: 1,350 mm
- Cylindrical length: 2,300 mm
- Loading length: 1,500 mm
Dimensions & Weight:
- Autoclave L × W × H: 4,000 × 2,200 × 2,200 mm
- Autoclave weight: 4,800 kg
- Control cabinet L × W × H: 2,400 × 600 × 2,100 mm, weight: 1,200 kg
- Silencer L × Ø: 1,300 mm × Ø 168.3 mm, weight: 40 kg
Dkedpoxrt Shofx Ah Uow
- Total system weight: approx. 6,000 kg
Electrical Data:
- Operating voltage: 400 V AC ±10%, 50 Hz ±1 Hz
- Control voltage: 230 V AC / 24 V DC
- Power consumption: approx. 68 kW
- Current consumption: approx. 120 A
Pneumatic Data:
- Control air for regulation: 8–10 bar
- Max. pressure at autoclave air inlet: 35 bar (before regulating valve group)
- Max. dust/particle size: ≤ 3 µm
Cooling Water:
- Cooling water pressure: 2–6 bar
- Cooling water consumption: 8.0 m³/h
Performance / Autoclave operation:
- Temperature range: 0–400 °C
- Max. operating pressure: 20 bar
- Test overpressure: 26 bar
Loading weight:
- Steel racks & carts: max. 60 kg
- Composite: approx. 20 kg
- Max. temperature increase (20 → 400 °C): 5 °C/min (approx. 76 min)
- Max. temperature decrease (400 → 60 °C): 5 °C/min (approx. 68 min)
Environment & Emissions:
- Operating temperature range: +5 to +40 °C
- Max. relative humidity: 90 %
- Max. altitude above sea level: 1,000 m
- Autoclave noise emission (1 m distance): ≤ 60 dB(A)
- Piping system noise emission: ≤ 80 dB(A)
- Short-term noise emission of air duct (1 m distance): ≤ 120 dB(A)
- Autoclave: 4,800 kg
- Control cabinet: 1,200 kg
- Silencer: 40 kg
- Total weight ≈ 6,040 kg (~6 tons)
Scope of Delivery:
- Hot air autoclave including quick-release closure
- Heating and cooling system
- Air and cooling water distributor
- Piping and cabling
Note:
Missing technical data (e.g., dimensions, weight, performance details) will be provided later. Buyer is responsible for installation and operation.
Contact:
For inquiries or further questions regarding the system, feel free to contact us. A viewing can be arranged by appointment.
(Changes and errors in technical data and details excepted!)
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Send inquiry
Telephone & Fax
+49 2861 ... show
Your listing has been deleted successfully
An error has occurred