Climatic test chamber 800 L, -55°C to +180°CWeiss
ClimeEvent C/800/55a/25/S 25K/min
Climatic test chamber 800 L, -55°C to +180°C
Weiss
ClimeEvent C/800/55a/25/S 25K/min
Year of construction
2020
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Climatic test chamber 800 L, -55°C to +180°C
- Manufacturer:
- Weiss
- Year of construction:
- 2020
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A19821050
- Reference number:
- 24761
- Update:
- 22.08.2025
Description
Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Hedsw R Rt Ispfx Ad Dofp
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
The listing was translated automatically. Translation errors are possible.
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Hedsw R Rt Ispfx Ad Dofp
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Rimini
8,475 km
Tensile / Compression testing machine
ZwickRoell GmbHZ005TN
ZwickRoell GmbHZ005TN
Listing
Sonsbeck
7,609 km
Tensile Testing Machine-Universal Testing Machine
Richard Hess MBV GmbHH5TMCI
Richard Hess MBV GmbHH5TMCI
Listing
Sonsbeck
7,609 km
Tensile Testing Machine-Universal Testing Machine
Richard Hess MBV GmbHH3000-H5000TM mit Langwegextensometer
Richard Hess MBV GmbHH3000-H5000TM mit Langwegextensometer
Listing
Borken
7,621 km
Instron 34TM-50 50kN Serie 3400
Instron 34TM-50 50kN Serie 340034TM-50 Zug und Druckmaschine
Instron 34TM-50 50kN Serie 340034TM-50 Zug und Druckmaschine
Listing
Borken
7,623 km
Climate chamber
VötschVC³ 4060
VötschVC³ 4060
Listing
Wiesbaden
7,810 km
Rockwell hardness tester
REICHERTERBriro-Pedal
REICHERTERBriro-Pedal
Listing
Jena
7,950 km
(2x) Climate chamber for stability testing
ThermoTEC / VIESSMANNWL80
ThermoTEC / VIESSMANNWL80
Listing
Borken
7,623 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
VötschVC³ 4100 990 Liter -42°C bis +180°C
Listing
Borken
7,623 km
Temperature shock test chamber
CTSTSS-70/130 +50°C...+250°C -80°C...+100°C
CTSTSS-70/130 +50°C...+250°C -80°C...+100°C
Listing
Borken
7,623 km
Environmental test chamber -70°C - +180°C Humidity
ThermotronSM-8-8200
ThermotronSM-8-8200
Your listing has been deleted successfully
An error has occurred