Used Measuring & testing equipment for sale (1,317)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Listing

7,623 km
Emission test chamber 480 liters
VötschVCE 1000/S +20°C bis +130°C
Call
Condition: excellent (used), Here we offer you a Vötsch emission chamber.
Water cooled
Test chamber volume 1000 liters (usable) (916) liters Adjustment tank 480 liters
Performance for temperature tests:
Temperature range +20°C to +130°C
Temperature deviation temporal K ±0.1 to ±0.3
Temperature deviation spatial K ±0,5
Temperature gradient K 1
Temperature rate of change:
Cooling K/min 0.3
Heating K/min 0,4
Performance for climatic tests:
Carrier gas conditioning with climatic module
according to the evaporation principle
Temperature range +20°C to +130°C
Humidity range 5 to 95%
Dew point range +5°C to +60°C
Humidity deviation in time % ±1 to ±3
Carrier gas exchange rate 0.1 to 1.8 chamber volume per hr.
Capacity range for desorption
Desorption temperature up to max. +240°C, adjustable
Test chamber surface temperature between +220°C and +240°C
Purge rate max. 4 m³/h
Test chamber dimensions: Width 750 mm Depth 1630 mm Height 750 mm
test chamber door 670 x 670 mm
Outer dimensions: Width 1350 mm Height 2950 mm Height 2050 mm
rated current 32 A
nominal power 19,0 kW
Electrical connection 3/N/PE AC 400V ± 10% 50Hz
Weight 1200 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VCE 1000/S
Condition: used / used
Cgeliei Hbyljn Silst
Scope of delivery: (See picture)
Sale ex location
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,870 km
Optical Measurement System
KeyenceLS-9000
Call
Condition: ready for operation (used), Two Keyence optical LED light-band micrometers are available. Repeatability: +/-0.03µm, sampling rate: 16000 measurements/s, light source: green InGaN LED. Documentation available. On-site inspection is possible.
Cgolinov R Exuj Siljt
Listing

8,404 km
Multisensor CMM
WerthScopeCheck 400
Call
Condition: good (used), Year of construction: 2008, Functionality: limited functionality, Measuring range 400x400x200
Cjlielmlkken Siljgt
- Zoomlens
- LED ringlight
- LED stage light
- LED coaxial light
Probe:
- Renishaw SP25M
Software
- Windows XP
- Winwerth
machine and PC are working but Software must be installed new,
no software media available

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month
Listing

7,786 km
Highend Multisensor CMM
Profitech Industrielle Messtechnik GmbHAIM 553 // SONDERANGEBOT Demogerät
Call
Condition: as good as new (ex-display), Year of construction: 2021, AIM coordinate measuring centers are the
technical successors of the Mahr
Mahr multisensor coordinate measuring
coordinate measuring machines.
Technical data:
Measuring range: 500 x 500 x 300 mm
Dimensions: 1520 x 1040 x 2040 mm
weight: approx. 1.200 kg
max. workpiece weight: on glass plate approx. 40 kg
Accuracies: U1=1,9 + L/200
U2=2,4 + L/150
U3=2,9 + L/100 (L= measuring length in mm)
increased accuracy on request
traversing speed: 200 mm/s
Cgolijg Ewk Ren Silet
acceleration: 400 mm/s
scale resolution: 0.0001 mm
Multisensor sensor unit (MSH) optical/tactile/laser
-incl. high-precision USB camera with 2-stage zoom with telecentric
beam path
-incl. PTL01 TTL point laser, highly accurate, telecentrically coupled in
-incl. Renishaw TP200 integrated tactile probe system, optionally extendable
-incl. Quad-Light LED Power Ringlight, programmable incident light
-incl. LED power transmitted light
-incl. Nikon precision lens 5x (optional 3x, 10x, 20x, 50x) C-Mount
Technology
-incl. calibration standard with factory calibration certificate, consisting of glass plate "circle", calibration sphere and ring gauge
Transfer
-State-of-the-art PT200 CNC controller system in a solid, industry-standard
control cabinet
-PCI-BUS system for fast internal data transfer in real-time operation
-Extendable 19" controller rack for optimum access in case of servicing
-modular controller concept open for later upgrades and retrofits
-service-optimized controller design fast access and service times
-Integrated 64-bit broadband bus technology with Ech
[...]
Listing

7,623 km
Temperature shock test chamber
Weiss130 Liter TS 130 50010
Call
Condition: excellent (used), Here we offer a temperature shock test cabinet.
White Temperature Shock Test Cabinet Air Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 sec.
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Cgelinjn Aq Ufs Silst
Further questions we can answer on the phone for you.
Listing

8,404 km
Coordinate measuring machine
MitutoyoEuro C9166 Apex
Call
Condition: excellent (used), Year of construction: 1999, Mitutoyo Euro C9166 Apex
Measuring ranges 900x1600x600mm
Accuracy 2,9 + 4L/1000µm
Software selectable:
- Mitutoyo MCOSMOS-1 V3 (upgrade V5 for € 4.000,--)
- EasyCMM I++ Server plus Inca Professional (€ 8.000)
Probe Renishaw PH1 with either:
- Renishaw Touch probe TP200
- Renishaw Touch Probe TP20
Cjlin Sshtqxusilsgt
Selectable options:
- Renishaw PH10 (T oder M)
- New PH10M or Tplus Head and Probe (upgrade)
- Bilz Pneumatic Vibration Damping System
on demand Installation & Calibration and software training
(plus additional travel expenses)
Including 3 Month Warranty on machine and probe
(excl. travel expenses)
Listing

7,623 km
Climatic chamber
Vötsch VC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climate test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Device dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Rate of temperature change:
Heating 4.0 K/min
Cooling 3.0 K/min
max. heat compensation at +20°C 4500 Watt
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Spatial temperature homogeneity ± 0.5 to ± 1.0 K
Celinoqnutmo Siljgt
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after a successful check, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature shock chamber
EspecTSA-201 SW
Call
Condition: excellent (used), Espec Temperature Shock Chamber
Here we offer you an Espec temperature shock chamber.
Thermal shock environmental chamber (cold load: -65° to 0°C). Conventional thermal shock chambers with three zones can be quite large because three separate chambers are used.
The TSA series has only one chamber, significantly reducing its size. Instead, it circulates cold, hot or ambient air as needed.
The conditioned air can be precooled or preheated beyond the set point, allowing for faster recovery to the desired condition after transfer.
Espec Temperature Shock Chamber Water Cooled TSA-201S SN: 153000154
Hot chamber: +60 to 200°C Cold chamber: -70 to 0°C
Working temperature: 0-40°C
System: two zone or three zone test by flap switching.
Performance:
Cgelin Sog S Ugksilet
Test range:
High temperature. Exposure range: +60 to +200°C
Low temperature. Exposure range: -70 to 0°C
Temperature variation ±0.5°C
Hot chamber:
Temperature Heating time: ambient temp. to +200°C within 15 min.
Cooling chamber:
Temperature Pulldown time: ambient temp. to -75°C within 45 min.
Temperature recovery: within 10 min.
Inner dimensions (W x H x D mm): 650 x 460 x 670
External dimensions (W x H x D mm): 1550 x 1900 x 1670
Power supply: 380/400/415V AC 50Hz: 70 A
Refrigerant: R404/R23
Weight: approx. 1400 kg
Type: Espec Model: TSA-201 SW
For you as a buyer, the following information for your safety!
The following points are checked on our offered chambers in advance.
Listing

7,623 km
Analytical drift detector
Oxford InstrumentsINCAx-act
Call
Condition: excellent (used), Oxford Instruments
Here we offer you an INCAx-act Analytical Drift Detector.
Microanalysis of elements including boron and above
Colin Siohx Nchslsgt
Operating temperature
Normal mode 10-25 degrees
Operating temperature
extended mode 10-30 degrees
Storage temperature
-25 to 40 degrees and 8 to 80% humidity non-condensing
Operating humidity
Listing

7,623 km
Vibration test system
RMSSW 3006 mit TGA 1500
Call
Condition: excellent (used), RMS Vibration Test System
Here we offer you a RMS electrodynamic vibration test equipment.
RMS Vibration Test System
Vibration exciter SW 3006
Power amplifier TGA 1500
Technical data:
Sine:3,7 kN
Noise:3,7 kN
Shock:3.7 kN
Displacement pk-pk:26 mm
Speed: 0.9 m/s
Acceleration: 80 g
Cooling: air cooled
Condition: used / used
Untested! Tests were not possible
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Coliohyly Rjn Siljgt
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing

7,623 km
Chamber convection oven
EliogKU 300/09-06-06/2
Call
Condition: excellent (used), Eliog
Here we offer you a chamber air circulation furnace.
Usable space dimensions : height mm 900 / width mm 600 / depth mm 600
324 liters
Outer dimensions : height mm 1775 / width mm 900 / depth mm 953
Door leaf 1
Connected load: 3X400V 50 Hz 13 kVA
Heating power: 12 kW
Nominal temperature: 300°C
Cslinjifkiio Silegt
weight: 400 kg
Type: KU 300/09-06/2 K1051071
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Temperature test chamber ex protected
CTS-30°C bis +80°C T-30/950 Ex/I
Call
Year of construction: 2011, Condition: excellent (used), Here we offer you CTS temperature test chamber.
Control-32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of the setpoints
Error messages in plain text
Interface RS 232
Free switching channels for on-site test material control
Temperature tests:
temperature range -30°C to +80°C
temperature deviation ±0,3 K temporally
Temperature change rate
heating 2 K/min
Cooling 1.5 K/min to -10°C
Heat radiation approx. 1000 W at +20°C
approx. 200 W at -25°C
Data for gas supply:
Temperature range: -25°C to +55°C
Temperature deviation: ±0.25 K to the test space
Temperature change rate measured on average at a gas flow of 10 Nm³/h: at least as fast as the test chamber
Data for the gas return:
Temperature range: +18°C to +30°C
Temperature deviation: ±0.25 K to the test chamber
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with the large purge volume N2 until the
oxygen content is less than 3%. After that, the system switches to a base load (approx. 10% of the large flush volume).
is switched over.
The nitrogen flow rate of the base load is measured with a flow meter, displayed and monitored by a limit switch.
and monitored by means of a limit switch.
The O2 monitoring system continuously extracts from the test chamber via a flashback arrestor
gas from the test chamber via a flame arrester and passes it over an O2 sensor that monitors the residual oxygen content of the extracted air.
The gas is then returned to the test chamber via a second flashback arrestor.
test chamber. The exhaust pump is monitored by a volumetric flow meter. Further details can be found
can be found in the Dräger operating instructions in the appendix.
The gas device is currently out of service!
The technical data refer to an ambient temperature of +25 °C,
Nominal voltage 400V , without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 950 liters
Test chamber dimensions height approx. 700 mm / width approx. 900 mm depth approx. 1500 mm
External dimensions height approx. 2400 mm / width approx. 1270 mm depth approx. 3125 mm
Operating data:
Electrical connection 400V+6/-10 %, 3/N,50 Hz
rated power 21,6 kW
rated current: 36,5 A
Protection class IP 54
condensate drain pressureless R 1/2" female thread
Sound pressure level < 62 dB(A)
(according to DIN EN ISO 3744
measured at 1m distance from front)
weight: approx. 1500 kg, control cabinet approx. 300 kg
Cslinsihb Ame Silogt
external refrigeration unit
refrigerant R404A / R23
Type: T-30/950 Ex/I
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Universal tensile testing machine 2000 kg
HaidaHD-B604-S 20 kN
Call
Condition: excellent (used), Haida
Type: HD-B604-S
Sensor: TECSIS load cell
Max. Capacity: 2T / 20 kN
Unit: G, kg, N, LB (adjustable)
Resolution: 1/250,000
Accuracy: ± 0.5%
Max. Stroke: 700 mm (without fixture)
Test speed: 0.1-500mm/min (adjustable)
Voltage: 220V AC ± 10%, 50/60Hz
Clamping jaws: 0-7 mm
Weight: approx. 175 kg
Dimensions (WxDxH): 88 x 50.5 x 150 cm
Condition: used
Scope of delivery: (see picture)
Cgjlinjr Ixq Rs Siljt
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate test chamber 2500 liters
VötschVC 4200/S -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Cslin Sisu Au Utoljgt
Type: VC 4200/S
Climate test chamber 2500 liters water-cooled
Temperature test:
Temperature range -40°C to + 180°C
Temperature deviation in time: ± 0.3 to ± 1.0
Spatial temperature deviation: ± 1.0 to ± 2.0
Temperature gradient 2 to 4
Heating speed: 2.0 K/min
Cooling rate: 3.0 K/min
Climatic tests:
Temperature range: +10 °C to +90 °C
Temperature deviation over time: ± 0.1 to ± 0.5
Temperature deviation over time: ± 1 to ± 1.5
Temperature gradient 2 to 3
Humidity range: 10% to 98% r.h.
Humidity deviation over time: + 1 to 3 % r.h.
Dew point range +5 to +89°C
Test room dimensions: Width approx. 2000 mm x depth 1150 mm x height 1150 mm
External dimensions: Width approx. 3500 mm x depth 1450 mm x height 2100 mm
Nominal voltage 3/N/PE AC 400 V ±10%50Hz
Rated power 13 kW
Nominal current 21 A
Refrigerant R-452A
Weight approx. 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature chamber
HeraeusHT/S 7050
Call
Condition: excellent (used), Heraeus temperature chamber
Here we offer a temperature chamber.
Water-cooled
Outside: W x D x H (mm) 1100 x 2200 x 2320
Inside: W x D x H (mm) 800 x 800 x 790
Test chamber volume 500 L
Characteristic values for temperature tests:
Temp. range -70°C to +180°C
Heating speed: 3 K/min
Cooling speed: 2 K/min
Electrical power:
Rated power 15 kW Rated current 26 A
400 V +6/-10% 3/N 50Hz
Weights: 675 kg
Type: HT/S 7050
R404 A and R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Cgolin Siju Efm Sslst
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber
Vötsch VT 4021
Call
Condition: used, Heraeus Vötsch
Type: VT 4021
Heraeus Vötsch temperature test chamber air-cooled
Housing dimensions: Width 850 mm Depth 1250 mm Height 1640 mm
Interior: Width 560 mm Depth 570 mm Height 630 mm
Temperature range -40°C to + 180°C
Temperature deviation in time ±0.2 to ±0.5 K
Spatial temperature deviation ±0.5 to ±1.5 K
Temperature change rate cooling 3.1 K/min
Temperature change rate heating 2.5 K/min
Nominal voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 1.5 kW Rated current: 7 A
2X side feed-through 90 mm
Refrigerant: R-404A
Weight approx. 325 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
Cjlin Ssu Hf Hhoilegt
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS
Climatic test chamber T-70/600 water-cooled
Temperature range: -70°C to +180°C
Rated voltage: 400V 3/N PE 50 Hz
Rated power: 6.7 kW
Rated current: 10.2 A
Compressor: TFH2480Z/TFH2511Z Refrigerant R23/R404A
Control system:
-Microprocessor-controlled control and monitoring system
Simple, user-friendly terminal built into the door.
-Digital temperature setpoint and actual value display
Simple variation via +/- button
Cslin Ssvaxq Neiljgt
-Digital input for temperature in °C
-PLC compatible
-Up to 100 test programs possible
-RS 232 interface
-2 free switching channels for on-site
test material control
Insert grid:
Stainless steel, contact surface 820 x 710 mm
Load per grid max. 35 kg
Total load with max. grid configuration 100 kg
Cooling unit:
Water-cooled, low-noise, fully hermetic Infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
Temperature tests:
Temperature range -70 °C to+ 180 °C
Temperature deviation ±0.1 to 10.3 K in time
Rate of temperature change
according to DIN 50 011, part 12 measured in the center of the test room
Heating 2.5 K/min
Cooling 2 K/min
Heat radiation max. 1500 W at +20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x Dx H)
External dimensions 1050 x 1850 x 1900 mm (W x DxH)
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current: 10.2 A
Protection class IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Laboratory furnace
DespatchLCC1-16NV-3
Call
Condition: excellent (used), Here we offer a Despatch lab oven.
Despatch Laboratory Ovens
+ 8 "WAFER
LCC: Maximum temperature 260 ° C
Lockable circuit breakers turn on the control panel for easy maintenance
Protocol 3 control with large LCD display, built-in data logging capabilities and USB port for easy oven setup and data export
Cgeljd Nfq Ioin Silst
Edelstellenne room with interior seams welded continuously on the insulation side to protect the working space from pollution
Programmable door locking prevents the operator from opening the oven door while the cycle is running
The door lock switch turns off the heating when the door is open
The rolled air flow consists of 100% HEPA (High Efficiency Particulate Air) and is filtered to ISO Class 5 (Class 100) throughout the process cycle
The Magnehelic Manometer monitors the pressure drop of the HEPA filter so you know when to replace the filter
Electric door unlocking for ergonomic operation
UL & C-UL Listed Control Panel Open
Modbus communication connection (RS485) for remote monitoring and recording
Chamber measure L 350 mm
Chamber measure B 350 mm
Chamber Measure H 350 mm
Maximum temperature 260°C
Digital screen Yes
Electric connection 230 V
Total size L 830 mm
Total dimensions B 910 mm
Total Measure H 560 mm
Type: LCC1-16NV-3
Condition: used/used
Delivery: (See picture)
(Changes and errors in technical D
Listing

7,623 km
Vibration test system
RMSSW 1507 / TGA 1500
Call
Condition: excellent (used), RMS vibration exciter with power amplifier and cooling fan
Here we offer you a RMS vibration exciter with power amplifier.
Vibration exciter SW 1507
Max force 2158 N
max. speed 1,3 ms
Power amplifier TGA 1500
3 x 380V/ 50Hz/ 35A / 8 kVA
Condition: used / used
Cslinjgkaibe Silegt
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing

7,623 km
Temperature chamber
WEISSWT1-340/30
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer Weiss temperature chamber.
Converted to R452a
Weiss temperature chamber air cooled
Temperature range: from - 30°C to 180°C
Temperature change rate cooling 1,6 K/min
Temperature change rate heating 2,1 K/min
Test chamber dimensions: Width 550 mm x depth 750 mm x height 800 mm
Colin Sisic Rgfelogt
Housing dimensions: Width 800 mm x depth 1500 mm x heights 1800 mm
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4,9 kW Rated current 9 A
Refrigerant: R452a
Weight: 515 kg
Type: WT1-340/30
For you as a buyer the following information for safety!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Cslin Siorbiyfslogt
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

7,623 km
Salt spray test chamber Climate change test
WeissSC / KWT-1000 1000 Liter
Call
Condition: excellent (used), White
Type: SC / KWT - 1000
Technical data:
Salt spray mist test MIN 5 K > Tu MAX +50°C
Condensation water test MIN 5 K > Tu MAX +45°C
Humidifier MIN 5 K > Tu MAX +75°C
Cgjlijrh Dmqen Silet
Temperature constancy
The temperature deviation over time is ±1 K
Dimension with hood:
Test chamber: H 1190 mm x W 1650 mm x D 570 mm
Dimensions without hood:
Test area: H 740 mm x W 1650 mm x D 570 mm
Dimensions with hood:
Outside: H 1370 mm x W 2730 mm x D 800 mm
Dimensions without hood:
Outside: H 920 mm x W 2730 mm x D 800 mm
Capacity approx. 700 - 1130 liters
3/N/PE AC 400V ±10%50Hz
Rated power 4 KW Rated current 7.5 A
Weight: 180 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Vacuum drying oven
HeraeusVT 6025 200°C
Call
Condition: excellent (used), Heraeus
Type: VT 6025
Heraeus Vacutherm vacuum drying oven
Specification jacket heating VT 6025
Temperature (metric) 200 °C
Dimensions, inside (W x D x H): 300 x 307 x 275 mm
External dimensions (W x D x H): 480 x 450 x 600 mm
Electrical requirements 230 V, 50/60 Hz
Frequency 50/60 Hz
Capacity (metric) 25 l
Heating jacket type without inert gas connection
Voltage 230 V 1.3 kW, 5.9 A
Weight: 58 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Celijrm Rihsn Silsgt
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature shock test system
RS SimulatorenST2K320/45 K
Call
Condition: excellent (used), RS. simulators
Type: ST2K320/45 K
Water-cooled shock test system
Temperatures in the upper test chamber
Temperature range: + 40 °C to + 180 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Temperatures in the lower test chamber
Temperature range: - 40 °C to +100 °C
Cgslinstrf Ulj Silot
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Humidity in the upper test room
Climatic temperature range: + 40 °C to +90 °C
Humidity range: 20 % to 98 % (± 2 to 5 %) relative humidity
Humidity: 25% to 75% relative humidity
Working climate range:
Temperature: + 12 °C to + 30 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 900 mm Height 2000 mm Depth 2300 mm
Test room dimensions: Width 470 mm Depth 700 mm Height 440 mm
Electrical power supply:
Total power: 13 KVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate chamber 38m³ Sunlight simulation
WeissWK 40'/40-120/So -40° bis +120°C
Call
Condition: excellent (used), Internal dimensions (net) H approx. 2150 mm W approx. 3000 mm D approx. 6000 mm
Air circulation system (on chamber rear wall) Width approx. 800 mm
External dimensions with machine unit and without control cabinets
Height approx. 3360 mm Width approx. 3320 mm Depth approx. 8620 mm
Machine room, attached to the rear wall of the chamber
Height approx. 2340 mm Width approx. 3320 mm Depth approx. 1500 mm
Electrical control cabinet, mounted on the side of the base frame
Height approx. 2340 mm Width approx. 2400 mm Depth approx. 600 mm
Chamber door (double-leaf)
Height approx. 2150 mm Width approx. 3000 mm
Pedestrian door (single-leaf)
Height approx. 1900 mm Width approx. 900 mm
Lighting (switch next to pedestrian door)
4 incandescent lamps 60W
Feed-throughs 4 pcs. 125 mm ∅
Floor load capacity
30,000 N/m² (surface load);
2,500 N per polyamide wheel Ø100mm;
4,000 N for a wheel with 4 cm²
Ceiling opening (clear dimensions of the lower disk)
Length approx. 600 mm Width approx. 700 mm
Quantity: 10 pieces
Ceiling load: 10 SoSi radiators + 1 person 90 kg
Working temperature range:
Temperature range -40 °C ... +120 °C (discontinuous)
Cooling speed:
approx. 1 K/min. linear from 80°C to -40°C with test specimen mass and without thermal load,
measured in the air outlet of the air circulation system.
At temperatures < (-20°C) the recirculated air volume is reduced by 50%.
(e.g. PV 1200)
Heating speed:
approx. 1 K/min. linear from -30°C to +90°C with test specimen mass and without thermal load,
measured in the air outlet of the air circulation system.
(e.g. PR 308.2)
Test specimen mass: 600 kg aluminum (vehicle - partial body)
Working range climate without sunlight simulation:
Temperature range: +10 °C ...+95 °C
Temperature constancy: ≤ ± 0.5 K (temporal)
Temperature constancy: ≤ ± 2 K (spatial)
Humidity range: 20 ... 80 % r.h., without thermal load
Cgolinetrmm Ns Silst
Dew point temperature range: -2 °C ...85 °C without thermal load
Climate working range with sunlight simulation:
Temperature range: +23 °C ...+50 °C
Temperature constancy: ≤ ± 0.5 K (temporal)
Humidity range: 20 ... 70 % r.h., with thermal load
Dew point temperature range: -2 °C ...43 °C without thermal load
Thermal load of the SoSi: Max. 10 kW
Temperature and humidity instances:
Temperature
The following maximum deviation is specified for the temperature in the climate and temperature range
(including measurement uncertainty and with test material):
Blow-out after 15 minutes: ±1K
Intake after 45 minutes: ±1.5K (external sensor)
Humidity
For the relative humidity at the operating point 80°C / 80% r.h.
the following maximum deviation (including measurement uncertainty and with test material) is specified:
Blow-out after 30 minutes: ±3% r.h.
Intake after 60 minutes: ±3% r.h. (external sensor)
Connection and consumption data:
Air-cooled refrigeration unit, maximum air temperature +38°C
Refrigerant R 404 A and R23
Water supply for humidifier:
Approx. 40 l/h = 40 kg/h installed steam output,
demineralized water, electrical conductivity 5-20 μS/m
Mains connection: 400 V; 3 PH + N + PE; 50 Hz
Connected load: 250 kVA, 350 A
Connection according to VDE 0110 group 2: 5x185 mm2 CU
On-site fuse protection: 355 A
Air circulation volume (FI-controlled): 24,000 to 28,000 m³/h
FC basic setting: 50% (achievement of the parameters)
Technical data solar simulation:
Manufacturer: BF Engineering GmbH
Type: G-BEM-1119
Number of lights: EPSU 2 x 2k_HQI
Ballast: 10
Ignitor: IGC-4k-03
Light source: OSRAM HQI 2000W High Flux
3〜/ N / PE
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Measuring & testing equipment (1,317)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month