Used Testing for sale (10,784)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Germany
7,870 km
Filter Test Mystem
LorenzFMP 04
Call
Year of construction: 2021, condition: ready for operation (used), An automatic Lorenz filter test station for the automatic testing of filter media, half masks, canister filters, and medical face masks is available. Standards: EN143/EN149/EN14683/ISO16900-3 and more, module components: flow meter/photometer upstream and downstream of the test specimen/aerosol generator/suction and extraction unit, aerosols: paraffin oil/Emery oil/DOP/DEHS, volume flow range: 8L-300L/min, min. separation efficiency measuring range: 0.0001%, min. breathing resistance measuring range: 5Pa-1000Pa, max. filter air velocity: 10.2cm/s, max. test area: 237.8cm³. The device has been used little and would not need to be serviced. Documentation available. An on-site inspection is possible. The image is an example.
Lsdpfxsy Tx Sls Abneac
Listing
Viersen
7,634 km
Safety tester test device
EatonSefelec 506-S + 64-SC
Call
Condition: excellent (used), Year of construction: 2024, functionality: fully functional, Safety tester with scanner for high-voltage test station
- EATON Sefelec 506-S
- EATON Sefelec 64-SC
The devices were purchased in 2023/2024 and are in top condition.
The SEFELEC 506-S test device for electrical safety testing, an EATON next-generation model, is based on ARM dual-core technology components and is controlled via DSP. This technology offers the operator optimal stability and repeatability of measurements.
The high accuracy and measurement speed are tailored to the requirements of quality assurance in production and incoming goods inspection.
The sequence function facilitates the operation of the SEFELEC 506-S test station when integrated into a test stand or test bench.
The 7” touchscreen of the new SEFELEC model series impresses with simple and intuitive operation.
- Standard interfaces: Ethernet / RS232 / USB / PLC
- Optional: IEEE488-2 interface
- Dual safety circuit SIL2
- Automatic selection of test series
- Sequence mode for combining multiple consecutive tests
Voltage withstand at 5kVAC 500VA and 6kVDC
Detection modes by current threshold or current fluctuations (ΔI)
Burn function mode without current detection
Megohmmeter 200 GΩ, test voltage from 20 VDC to 1000 VDC
Ljdpjxqxw Tsfx Abneac
Optional: 2TΩ range
PE measurement at 32A - 8VAC, measurement 0 ... 1Ω
Optional: test current 50A
Programmable test ramps
Ramp up, hold, ramp down
Multi-ramp mode, up to 7 steps
TFT touchscreen 7”, 16 million colors, for programming, as well as for displaying ongoing tests and results
Integrated ARM dual core control & Nand 3D technology for optimal accuracy, stability and repeatability
Integrated DSP enables higher test speeds
Large internal memory for storing configurations and test results
Completely compliant with IEC 61010-2-034 (safety requirements for test and measurement equipment for insulation resistance measurement and equipment for voltage withstand testing)
Shipping is possible subject to prior agreement.
#8312-2
Listing
Viersen
7,634 km
Safety tester test device
EatonSefelec 506-S
Call
Condition: excellent (used), Year of construction: 2023, functionality: fully functional, Safety Tester for High Voltage Test Station
- EATON Sefelec 506-S
Lasdpexqxt Iofx Abnec
The device was purchased in 2023 and is in excellent condition.
The SEFELEC 506-S test device for electrical safety testing, an EATON next-generation model, is based on ARM dual-core technology components and is DSP-controlled. This technology offers the operator optimal stability and repeatability of measurements.
The high precision and measurement speed are tailored to meet the requirements of quality assurance in production and incoming goods inspection.
The sequence function facilitates the operation of the SEFELEC 506-S test station when integrated into a test stand or test bench.
The new SEFELEC model series features a 7" touchscreen that impresses with its simple and intuitive operation.
- Standard interfaces: Ethernet / RS232 / USB / PLC
- Optional: IEEE488-2 interface
- Dual safety circuit SIL2
- Automatic selection of test series
- Sequence mode for combining multiple consecutive tests
Withstand voltage at 5kVAC 500VA and 6kVDC
Detection modes by current threshold or current fluctuations (ΔI)
Burn function mode without current detection
Megohmmeter 200 GΩ, test voltage from 20 VDC up to 1000 VDC
Optional: 2TΩ range
PE testing at 32A - 8VAC, measurement 0 ... 1Ω
Optional: testing current 50A
Programmable test ramps
Ramp up, hold, ramp down
Multi-ramp mode, up to 7 steps
TFT touchscreen 7", 16 million colors, for programming and display of current tests and results
Integrated ARM Dual Core Control & 3D NAND technology for optimal precision, stability, and repeatability
Integrated DSP for higher test speeds
Large internal memory for storing configurations and test results
Fully compliant with IEC 61010-2-034 (Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2: Particular requirements for testing and measuring circuits for insulation resistance and dielectric strength)
Shipping is possible upon arrangement.
#8312-1

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,623 km
Temperature test chamber 1000 liters
WeissWT-1000/70/5 -70 °C bis +180 °C
Call
Condition: excellent (used), Weiss WT-1000/70/5 Temperature Test Chamber
For sale is a pre-owned temperature test chamber manufactured by Weiss, model WT-1000/70/5.
This unit is designed for precise temperature testing in industrial and laboratory environments, and is suitable for use in research, development, and quality assurance applications.
The test chamber allows for reproducible temperature cycles across an extended temperature range and is particularly suitable for material testing, aging tests, and stress tests under defined temperature conditions.
Technical Data
Manufacturer: Weiss
Model: WT-1000/70/5
Type: Temperature Test Chamber
Temperature Range: -70 °C to +180 °C
Temperature Deviation (over time, center of usable space): ± 0.1 to ± 0.5 K
Temperature Homogeneity (spatial): ± 0.5 to ± 2 K
Heating rate: 6.1 K/min
Cooling rate: 6 K/min
Test chamber volume: approx. 1000 liters
Test chamber dimensions (approx.): 950 x 1100 x 950 mm (H x W x D)
External dimensions (approx.): 2000 x 1415 x 2105 mm (H x W x D)
Lodpfx Asy D Nyujbnjac
Permissible total load, test chamber floor: 150 kg
Permissible load per shelf: 50 kg
Rated voltage: 3/N/PE AC 400 V ± 10% / 50 Hz
Rated current: 38 A
Rated power: 26 kW
Refrigerants: R404 / R23
Weight: approx. 955 kg
Features
- Water-cooled system
- Spacious test chamber
- High rate of temperature change
- Industrial grade construction
Condition
Used, with age- and use-related signs of wear.
Service / Inspection
For quality assurance, the following work is carried out on the offered systems:
- Function check and replacement of necessary components
- If required, refilling with legally compliant refrigerant
- Leak test with certificate
- Documented test run following successful inspection
Scope of delivery
- Weiss WT-1000/70/5 temperature test chamber
- Accessories as shown
Notes
- Connection via 400 V three-phase power required
- Shipping by freight carrier required due to size and weight
- Sale from commercial inventory
- All information subject to change
- Prior sale reserved
- For further information, feel free to contact us.
Listing
Borken
7,623 km
Climatic test chamber -42 to +190°C
MemmertCTC 256 256 Liter
Call
Condition: excellent (used), Memmert
Type: CTC 256
Memmert Climate Test Chamber CTC 256
Temperature & Humidity Test Chamber
Ledpey D Ni Aefx Abneac
Industrial Quality
For sale is a high-quality climate test chamber / temperature test chamber
from the manufacturer Memmert, model CTC 256.
The unit originates from professional use and is ideally suited for laboratories,
industry, research, development as well as quality assurance.
The Memmert CTC 256 is designed for precise simulation of temperature and climatic conditions.
It enables both cooling and heating processes and – in this configuration – humidity control.
This makes the unit perfect for material testing, aging tests, climatic stress tests,
and long-term experiments under defined environmental conditions.
Thanks to the integrated control system, complex test programs with temperature and time sequences can be set.
The forced air circulation system ensures uniform temperature distribution in the chamber interior.
Via the available interfaces, measurement data can be documented and processed externally.
Features:
Temperature and climate test chamber (heating & cooling)
- Humidity control
Electronic controller with programmable function
Forced air system for even temperature distribution
Internal protocol memory
USB and Ethernet interface
Additional 230 V socket
Feed-through (side)
Water container system (humidification/condensate)
Mobile on castors
Technical Data:
Manufacturer: Memmert
Model: CTC 256
Device type: Climate test chamber
Temperature range: approx. -42 °C to +190 °C
Internal volume: approx. 256 liters
Operating voltage: 3N~ 400 V / 50 Hz
Current consumption: approx. 10.6 A
Power consumption: approx. 7000 W
Protection class: IP20
External dimensions (approx.): 898 x 1730 x 1100 mm (W x H x D)
Internal dimensions (approx.): 640 x 670 x 597 mm (W x H x D)
Weight: approx. 300–350 kg
Condition: used
Scope of delivery: (see photo)
Memmert CTC 256 climate test chamber
Removable shelves
Water canister
Documents
Delivery as shown
(Specifications and technical data are subject to change and error!)
If you have any further questions, we would be happy to assist you by phone.
Listing
Hilden
7,668 km
Gear Testing Machine
OERLIKON-KLINGELNBERGR30
Call
Condition: used, Year of construction: 2007, max. wheel diameter 400 mm
Laedpjy D T Suofx Abnjc
workpiece dia. 36-300/400 mm
axis distance 135-290 mm
spindle turning speed - stepless 3000 1/min
dist. between centers 100-550 mm
Control Siemens 840D
weight of the machine ca. 4000 kg
dimensions of the machine ca. 2000x3055x2788 mm
Test method:
- Single flank rolling test
- Double flank rolling test
- Structure-borne noise test
- Heli testing in two-flank contact.
Features:
- Use of up to 6 test slides
- Highest testing accuracy and repeatability
- Machine table with workpiece drive
- Swiveling pneumatic unit
- Spray oil lubrication (type: Vogel)
- Oil mist extraction (type: Elbaron)
Listing
Győr
8,518 km
Temperature test chamber -72°C to +180°C
VötschVTS 7060-5 600 Liter
Call
Year of construction: 2016, operating hours: 14,242 h, condition: excellent (used), Vötsch temperature test chamber, water-cooled
Here we offer you a Vötsch temperature test chamber.
Vötsch 7060-5 water-cooled chanber
Test chamber dimensions: Height: 950 mm, width: 800 mm, depth: 800 mm
External dimensions: Height 1995 mm, width: 1090 mm, depth: 1960 mm
Test chamber capacity: approx. 600 liters
Year of construction: 2016
Operational hours: 14 242
Entry ports:
R1: NW 125 mm
L1: NW 50 mm
Data for temperature tests:
Temperature range: -72°C to +180°C
Temperature deviation in time in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature change rate
Heating 6.0 K/min
Lajdpfxst Txqrs Abnec
Cooling 6.0 K/min
Heat compensation at 20°C max. 5000 W
Heat compensation at -20°C max. 5000 W
Electrical connection:
Rated voltage: 3/NPE AC 400V ±10% 50Hz
Rated power: 13,0 kW Rated current: 23.0 A
Refrigerant: R-404A and R-23
Weight (approx.): 650 kg
The following information is for your safety as a buyer!
1. The chamber works perfectly.
2. No components have to be replaced.
3. Refrigerant is filled with legally compliant.
Condition: used (excellent)
(Changes and errors in the technical data, specifications are reserved!)
Listing
Burgoberbach
8,004 km
Climatic test chamber
FeutronKPK 200 Typ 3423/16
Call
Year of construction: 2011, condition: excellent (used), functionality: fully functional, For sale is a climate test chamber KPK 200. The unit is in very good condition and ready for immediate use.
Technical data:
Year of manufacture: 2011
Test chamber nominal volume: 280 dm³
External dimensions of chamber: 1500 x 2040 x 1075 mm
Minimum installation dimensions: 2060 x 1095 mm
Ledjy E Ilxjpfx Abnoac
With fan motor and door removed: 1500 x 1940 x 925 mm
Test space: 720 x 690 x 560 mm
Door, clear opening: 720 x 690 mm
Viewing window, heated: 500 x 600 mm
Number of shelves: 3 units
Maximum permissible load: 90 kg, evenly distributed across 3 shelves
Maximum load per shelf: 30 kg
Test chamber material: Stainless steel Wst.-Nr. 1.4301
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 4,748 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021,
total operating hours: 4748.2 h
For sale is a used temperature test chamber from Weiss Technik. This chamber is used for testing components and materials under various temperature conditions (e.g. cold, heat, aging).
Model designation explanation:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = low-temperature range (-70 °C)
e = energy-optimized design
5 = temperature change rate (model series)
Equipment features:
- Stainless steel interior
- Recirculating air fans
- Touch control (WEBSeason)
Lajdpfoy Dd Nqsx Abnjc
- Viewing window
- Automatic/manual temperature control
Technical specifications:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling approx. 6 K/min
Heating approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
For your peace of mind as a buyer, the following work is carried out on our chambers prior to sale:
1. Functional inspection and replacement of any necessary components
2. New filling with legally compliant refrigerant when required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in technical data and specifications reserved!)
For further questions, please feel free to contact us by phone.
Listing
Germany
7,870 km
Flying Probe Test System
SeicaPilot V8 Auto-SW-001
Call
Year of construction: 2019, condition: ready for operation (used), A Flying Probe Tester Seica Pilot V8 Next Series with inline handling module on the left for vertical tilting of the PCB and inline handling module on the right for horizontal tilting and rotating of the PCB is available. Flying Probe Test System Seica Pilot V8 Next Series: PCB clamping system: manual, double-acting, manual active test area: 538x610mm, active test area: 518x610mm, PCB dimensions: 540x610mm, min. PCB size: 20x20mm, PCB thickness: 0.3 to 5mm, max. component height: 37mm, PCB loading: vertical, UUT edge clearance manual/automatic: 2/6mm, length: 1750mm, width: 1030mm, height: 1995mm, weight: 1.4t. Test tools/techniques: FNODE signature analysis on the nets of the unit under test, standard analog and digital in-circuit test, vectorless tests, JSCAN and OPENFIX to test ICs for opens and shorts, PWMON net analysis with power-on of the assembly, continuity tests to detect open connections on the assembly, visual tests for detecting component presence, component absence and rotation, high-resolution color camera, optional functional tests and boundary scan test capabilities, optional on-board programming tools for digital components, with complete documentation. An inspection on site is possible.
Lasdpfx Aoy Sv S Hobnoc
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 5,128 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021
Operating hours: 5018 h
For sale is a used temperature test chamber from Weiss Technik.
This chamber is used to test components and materials under various temperature conditions (e.g., cold, heat, aging).
Meaning of the designation:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = low temperature range (-70 °C)
e = energy-optimized design
5 = temperature change rate (series)
Features:
- Stainless steel interior
- Recirculating air fans
- Touch operation (WEBSeason)
Ljdpey Dclwofx Abnoac
- Viewing window
- Automatic / manual temperature control
Technical specifications:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rates:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1300 kg
For your peace of mind as a buyer, please note the following:
The following procedures are carried out on all chambers prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see photos)
(Specifications and data are subject to change and errors reserved!)
If you have any further questions, we will be happy to answer them by phone.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 5,018 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021
Operating hours: 5018 h
For sale is a used temperature test chamber from Weiss Technik.
The test chamber is used for testing components and materials under various
temperature conditions (e.g., cold, heat, aging).
Designation meaning:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = low-temperature range (-70 °C)
e = energy-optimized version
5 = temperature change rate (series)
Features:
- Stainless steel interior
- Recirculation fans
Lajdpfx Aboy Dclqsnec
- Touch operation (WEBSeason)
- Viewing window
- Temperature control (automatic/manual)
Technical specifications:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3-phase
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1300 kg
For your peace of mind as the buyer, the following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical specifications!)
We are happy to answer any further questions by phone.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 5,128 h, condition: excellent (used), Weiss Temperature Test Chamber TempEvent T/1000/70e/5, water-cooled, 1000 liters, year of manufacture 2021, operating hours: 5128 h
For sale is a used temperature test chamber from Weiss Technik. This chamber is designed for testing components and materials under various temperature conditions (e.g. cold, heat, aging).
Model designation explanation:
T = Temperature test chamber
1000 = approx. 1000 liters capacity
70 = low temperature range (-70 °C)
e = energy-optimized version
5 = temperature change rate (series)
Equipment features:
- Stainless steel interior
- Recirculating air fans
- Touch operation (WEBSeason)
- Viewing window
- Automatic/manual temperature control
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (HxWxD)
Internal dimensions: approx. 950 x 1100 x 950 mm (HxWxD)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
Ledpfjy Dck Tox Abnsac
For your security as a buyer, please note the following information:
The following steps are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful checking, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see pictures)
(Specifications and technical details subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 4,748 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021,
running hours: 4748 h
Offered for sale is a used temperature test chamber from Weiss Technik. The chamber is used for testing components and materials under various temperature conditions (e.g., cold, heat, aging).
Explanation of the model designation:
T = temperature test chamber
1000 = approx. 1000 liter volume
70 = low temperature range (-70 °C)
e = energy-optimized version
5 = temperature change rate (series)
Equipment features:
- Stainless steel interior
- Recirculation air fans
- Touch control (WEBSeason)
- Viewing window
- Automatic / manual temperature control
Technical data:
Model: TempEvent T/1000/70e/5
Lsdey Dciispfx Abneac
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (HxWxD)
Internal dimensions: approx. 950 x 1100 x 950 mm (HxWxD)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerants: R449A / R23
Weight: approx. 1200 kg
Important safety information for buyers:
The following processes are carried out on the chambers we offer before delivery:
1. Function check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions by phone.
Listing
Hilden
7,668 km
Bevel Gear Testing Machine
KLINGELNBERG-OERLIKONT60 A
Call
Condition: used, Year of construction: 2007, max. wheel diameter 500 mm
Hypoid adjustment ±70 mm
axial cross angle 90 °
Distance Y- 150 - 350 mm
Distance Z-axis 120 - 340 mm
turning speed range - stepless 0 - 5000 U/min
max. torque on the spindle 57 Nm
Ljdpfx Abjukitxjneac
Cone 99,2 mm
Pull-in force Tool clamping 23000 N
Braking torque max. 93 Nm
total connected load 20 kVA
total power requirement 15 kW
weight of the machine ca. 6 t
dimensions of the machine ca. 2,35 x 2,24 x 2,5 m
Listing
Schweinfurt
7,931 km
Vibration test system with climate chamber
ETS SolutionsMPA102/L620M
Call
Condition: used, ETS MPA102/L620M Shaker Vibration Testing & Horstmann HS 220 Climate Test Chamber System
Vibration Testing System: ETS MPA102/L620M
Sine Force: 600 kgf
Random Force: 600 kgf
Shock Force (6 ms, half sine): 1,200 kgf
Max. Sine Velocity: 2 m/s
Max. Sine Acceleration: 981 m/s²
Armature Diameter: 200 mm
First Resonance Frequency: 3,300 Hz
Dimensions: 943 x 633 x 770 mm
Shaker Weight: 730 kg
Amplifier Unit: 6 kVA
Blower Unit: HP-2 / 4 kW
Climate Chamber: Horstmann HS220
Test Chamber Volume: 220 liters
Test Chamber Dimensions: 600 x 600 x 600 mm (H x W x D)
Temperature Range: -40 to +180 °C
Cooling Rate: 2 K/min
Lasdsy Sl Uqjpfx Abnjc
3 K/min
Heating Rate: 3 K/min
3 K/min
Electrical Connection: 400V, 3/N, 50 Hz / 5 kW
External Dimensions: 1,630 x 1,700 x 1,200 mm (H x W x D)
Used item as shown in the pictures.
Shipping:
The specified shipping costs apply to deliveries within Germany.
Worldwide shipping available (please inquire for shipping costs outside Germany).
The given shipping costs apply to shipping within Germany.
Sale only to commercial customers. No warranty or guarantee.
Deviations from the technical data as well as errors in the article description are possible and subject to change.
Listing
Borken
7,623 km
Universal test chamber +20 °C to +300 °C
MemmertUF 450plus
Call
Condition: excellent (used), Type: UF 450plus
Air circulation: forced convection
Temperature
Temperature range: +20 °C to +300 °C
Working range: at least +10 °C above ambient temperature
Setting accuracy:
up to 99.9 °C: 0.1 °C
from 100 °C: 0.5 °C
Temperature sensors: 2× Pt100 (DIN Class A, 4-wire)
Interior and Capacity
Volume: 449 liters
Internal dimensions (W × H × D): 1040 × 720 × 600 mm
Maximum number of shelves: 8
Load per shelf: 30 kg
Maximum total load: 300 kg
Interior: Stainless steel, all-around heating
External dimensions and Weight
External dimensions (W × H × D): approx. 1224 × 1247 × 784 mm
Net weight: approx. 160 kg
Gross weight: approx. 185 kg
Electrical Data
Voltage: 400 V, 3-phase
Power: approx. 5800 W
Control and Regulation
Controller: ControlCOCKPIT TwinDISPLAY
Regulator: digital PID microprocessor
Timer: 1 minute to 99 days
Functions: SetpointWAIT, HeatBALANCE, calibration at 3 temperature points
Adjustable parameters: temperature, fan speed, exhaust flap, time programs
Ventilation
Recirculating air: adjustable in 10% increments
Fresh air: electronically adjustable
Exhaust air: with throttle valve
Communication
Interfaces: Ethernet, USB
Software: AtmoCONTROL
Safety
Temperature limiter (TB), protection class 1
Temperature monitor/limiter (TWW/TWB) selectable
ASF system for over- and under-temperature monitoring
Equipment
Stainless steel door with 2-point locking
Stainless steel housing
Low-noise air turbine
Rear side with 2 feed-throughs approx. 12 cm diameter each
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in the technical data, information is non-binding!)
Ledpfxsyzzm Ie Abnjac
If you have any further questions, we are happy to assist you by phone.
For detailed technical data and processing instructions, we strongly recommend consulting the original datasheets or obtaining information directly from the manufacturer.
Listing
Borken
7,614 km
Temperature Test Chamber -40 to +100°C
FeutronTPK 3403/125
Call
Condition: good (used), Feutron Temperature Test Chamber: -40 to +100°C
Thanks to its robust construction, the Feutron TPK 3403/125 is a workhorse for standardized temperature testing.
The primary areas of application for this model are:
1. Electronics and Component Testing
This is the most common area of application. It focuses on how components react to extreme temperatures:
Functional Testing: Does the circuit board continue to operate flawlessly even at -40°C or +150°C?
Burn-In Testing: Artificial aging of components through continuous operation at high temperatures to induce early-stage failures.
2. Materials Testing
Investigation of physical changes in materials:
Brittleness: Do plastics or rubber seals become brittle in cold conditions?
Deformation: Do composite materials warp when exposed to heat?
Storage Testing: How stably do chemical substances or adhesives behave over extended periods at a constant temperature?
3. Quality Assurance (QA)
Sample Testing: In-process testing conducted alongside production to ensure that manufacturing output adheres to specified temperature ranges.
Standards Compliance Testing: Conducting tests in accordance with common industry standards (e.g., DIN EN 60068) that prescribe specific temperature profiles.
4. Research & Development
Prototyping: Testing new housing designs or materials under controlled thermal conditions prior to mass production. Manufacturer: Feutron
Model: TPK 3403/125
Temperature Range: -40 to +100°C
Refrigeration System: Air-cooled condenser
Temperature Stability: approx. ±0.1 to ±0.5 K
Usable Chamber Volume: approx. 125 liters
Refrigerant: R22
Operating Pressure: 23 bar
Power Supply: 220/280V-3-50Hz
Input Fuse Rating: 25 A
Protection Class: IP 20
Weight: 480 kg
"Everything from a single source: We would be happy to offer you suitable bank financing for your project."
komplett-konzept.leasingo.de
You can find additional items—both new and used—in our shop!
International shipping costs available upon request!
Lajdpfx Ajy Nynasbnoc
Listing
Schweinfurt
7,931 km
Vibration testing system shaker
Data Physics LE-1216-3VH 53,4kNLE-1216-3VH 53,4kN
Call
Condition: used, Designation: Vibration Test System
Manufacturer: Data Physics
Model: LE-1216-3VH
Force Rating:
Sine (5 - 2000 Hz)
Random (20 - 2000 Hz)
12000 lbf (53.4 kN) vector
12000 lbf (53.4 kN) rms
Frequency Range
Full Force
Reduced Force Level
5 to 3000 Hz
2500 to 3000 Hz
Maximum Displacement (Peak-Peak):
Rated Stroke Limit
Shock/Bump
Continuous or Random
Lajdpfxsy Rqiwe Abnoc
Electrical Overtravel Limit
Between Mechanical Stops
3.0 in (76 mm)
2.5 in (63.5 mm)
3.1 in (79 mm)
3.2 in (81 mm)
Maximum Velocity 71 in/s (1.8 m/s)
Maximum Acceleration
Sine 100 g vector, 5 to 2500 Hz
Random 50 g rms, 20 to 2000 Hz
Fundamental Resonance Frequency (Bare Table) 2050 Hz (nom.)
Body Suspension Natural Frequency — Thrust Axis:
- Vertical: 2 Hz
- Horizontal: Below 2 Hz
Blower Power (Full Load): 20 Hp, 20 kW;
230/460 V, 3-phase,
60 Hz
Alternate Power: 20 Hp, 20 kW; 208/400 V, 3-phase, 50 Hz
Air Pressure:
Air Spring:
- Vertical: 90-100 psig (621-690 kPa)
- Horizontal: 2-5 psig (14-34 kPa)
Field Specifications:
- Rated Current (dc): 64 A
- Maximum Voltage (dc): 240 V
- Field Resistance at 20°C: 3.2 ohm
Stray Flux Density with degauss coil: < 14 gauss at 12 in (304 mm) above table
Field Protection:
- Rated degauss coil current: 2.6 A (Nominal)
- Maximum degauss coil voltage: 120 V
Weight:
1216-3VH: 8000 lbs (3636 kg)
Power Amplifier Model: DSA10-80
Item condition:
Used item as shown in pictures
Armature newly rewound
Slip table / 40 mm grid M8 760 x 760
Armature bolt circles 8" / 16" M10
Please contact us if you have any questions.
Shipping:
The quoted shipping costs apply to deliveries within Germany.
Worldwide shipping (please inquire for shipping costs outside of Germany).
Sale only to commercial customers, without warranty or guarantee.
Deviations from technical data and errors in the description of the items may occur and are subject to change.
Listing
Čelákovice
8,178 km
Retrofitted gear testing machine GM
GEARTEC.CZRetrofitted GOULDER MIKRON
Call
Condition: excellent (used), Module range: 0,1 – 2 mm
Centre distance range: 25 – 85 mm
Vertical stroke of master gear slide: 40 mm
Diameter of measured gear, max. (clamped on arbor): 120 mm
Diameter of measured gear, max. (clamped between centers): 80 mm
Maximum distance between centers for clamping of measured part: 200 mm
Weight of measured gear, max.: 0,5 kg
Laedpfx Abjwkgr Ijnjc
Measuring force adjustment, manually adjustable: 0 – 8 N
Standard master gear arbor, diameter: 12,7 mm
Listing
Hochdorf
7,974 km
Temperature Cooling Unit (TCU)/ Chiller
SingleChill Plus Testing CHT-130
Call
Condition: new, *TECHNICAL SPECIFICATION:
Heating capacity: up to 36 kW per consumer circuit
Cooling capacity: up to 30 kW per consumer circuit at -30°C
Load circuits: 1 or 2 as standard
Temperature range: - 45°C to +130°C
Medium: water / glycol mixture
Dimensions LxWxH (without connections) :
1-circuit: 1950 x 1280 x 1725 mm
2-circuit: 2150 x 1640 x 1725 mm
Lodpsg Ezarsfx Abnjac
Weight:
1-circuit: approx. 1300kg
2-circuit: approx. 1500kg
*HIGHLIGHTS EQUIPMENT:
-Controls: Temperature control (standard)
-Control via SPS with touch screen
-Analogue and digital interfaces
-Internal 2-circuit pump system (INFO: Ensures performance values even at low flow rates)
-Heating control via solid-state relay (SSR)
-Flow measurement in the internal circuit for flow monitoring (INFO: If the water/glycol mixture is incorrect, the system automatically warns and switches off in the next step)
-Pressure-controlled cooling water regulator (INFO: Much more accurate than temperature controls)
Stainless steel tank, corrosion-resistant components (stainless steel/non-ferrous metal) (non-ferrous metal-free optional)
All medium-carrying components and piping insulated for low-temperature application
-Water-cooled condenser (air-cooled on request).
*OPTIONS:
-flow rate control: up to 100l/min, >4 l/min +/- 5% of measured value
-Pressure control: 0.5 to 4.5 bar (control range)
-compressed air monitoring
-test piece emptying by means of compressed air
- Cooling water monitoring
-Limitation of inlet pressure
-Other special options available on request and after technical inspection
Visit our website for more details or for other performance classes.
*This unit conforms to the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,623 km
Test cabinet EUCAR 5, CO₂ extinguishing system
Binder Batterie-TestschrankKB 720 Kühlinkubator mit Paket P Plus
Call
Condition: excellent (used), Year of construction: 2022, Binder
BINDER KB 720 Refrigerated Incubator with P Plus Package
Battery Test Chamber EUCAR 5, CO₂ Extinguishing System
Device Description:
For sale is a BINDER KB 720 (E6) refrigerated incubator, year of manufacture 2022, equipped with the upgraded safety and performance test package “P Plus.”
This is not a standard laboratory incubator, but rather a high-end safety test chamber specifically designed for aging, performance, and safety testing of lithium-ion energy storage systems.
The device is fully functional and has been tested. It originally sustained a transport-related housing damage, which has been professionally repaired and repainted.
Technically flawless – visually in very good condition
100% operational – no limitations
Price advantage: €1,000 cheaper than comparable units
Special Value Added:
The unit is designed to reliably detect, monitor, and safely contain critical battery events – up to EUCAR hazard level 5 (fire/flames, no explosion).
What exactly can the device do? (Item 2 – Performance & Application)
- Aging tests on lithium-ion cells
- Performance tests (charge/discharge cycles at temperature)
- Long-term temperature runs and thermal cycling tests
- Testing of unpowered and cyclical powered cells
- Reproducible, precise temperature control throughout the entire chamber
- Safe testing under realistic thermal conditions
- Test environment for R&D, automotive, e-mobility, and energy storage technology
Suitable for:
- Battery & cell manufacturers
- Research and development laboratories
- Test labs & safety testing
- Automotive / E-mobility / Energy storage sectors
The P Plus package turns the KB 720 into a genuine battery safety test cabinet:
Integrated Safety Features:
- Automatic & manual CO₂ fire suppression system
- Smoke detector with optical and acoustic alarm
- Mechanical double-door locking (secure containment)
- Spark protection inside chamber
- Exhaust port with reversible overpressure valve
- Connections for external inertization (e.g., nitrogen)
- Emergency stop / manual trigger of suppression system
- Cable feedthroughs for charging and measurement cables
Result:
The device is designed for testing lithium-ion cells up to EUCAR hazard level 5, where fire or flames may occur, but without explosion or uncontrolled propagation.
This is not an abuse or destruction testing device, but a compliant, safe test chamber for real-world operational and fault scenarios.
Technical Key Data:
Temperature range: –10 °C to +100 °C
Internal volume: approx. 698 liters
Shelves: 4 × stainless steel
Max. load per shelf: 45 kg
Max. overall load: 100 kg
Electrical Data:
Power supply: 200–240 V AC
Frequency: 50 / 60 Hz
Phase: single-phase
Power consumption: approx. 2.1 kW
Fusing: 16 A
Refrigerant: R134a
Protection class: IP 20
Dimensions & Weight:
Lasdpfx Ajyyw E Rebnsc
External (W × H × D): approx. 1250 × 1950 × 900 mm
Internal (W × H × D): approx. 970 × 1250 × 576 mm
In summary – why this device is special:
- Genuine battery safety test cabinet
- EUCAR hazard level 5 capable
- Integrated CO₂ extinguishing system
- Large chamber (≈700 l)
- High market and resale value
Weight: approx. 285–300 kg
Documents & Downloads
Condition: used
Scope of delivery: (see photo)
(Specifications subject to change and errors reserved!)
Further questions? Please feel free to contact us by phone.
Listing
Rödermark
7,854 km
Electrical test panel
PEISERFeG
Call
Year of construction: 1990, condition: good (used), Offer 26136
Technical data: (non-binding)
- Test panel for wall mounting with various testing devices
- Required space: W 600 x H 750 x D 300 mm
Lasdpfx Aoy Nldgjbnoc
- Weight: 40 kg
Listing
Wiefelstede
7,607 km
Test stand for filter testing
LorenzFMP 03 FH 143/149
Call
Year of construction: 2022, condition: good (used), Test stand for filter testing, filter testing, filter test system, filter measurement system, filter test system
-Manufacturer: Lorenz, Filter Test System Type FMP 03 with accessories
-Filter holder: Type FH 143/149
Lasdsyk Ahwjpfx Abnec
-Accessory case: with extensive contents
-Individual components/accessories: see photos
-Dimensions: 600/560/H975 mm / 640/460/H1130 mm / 430/340/H125
-Weight: 146.3 kg
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70/5 1000 Liter
Call
Year of construction: 2020, operating hours: 6,126 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70/5,
water-cooled, 1000 liters, year of manufacture 2020,
total operating hours: 6,126 h.
Lsdpfoyxm Uljx Abneac
Description:
For sale is a high-quality climate test chamber from Vötsch Industrietechnik
(Weiss Technik), model TempEvent T/1000/70/5.
This unit is designed for the simulation of temperature conditions and is ideally suited for:
- Material testing
- Electronics inspections
- Environmental and aging tests
- Quality and endurance tests
The chamber can achieve both very low temperatures down to approx. -70 °C and high temperatures up to +180 °C,
and can change temperatures at a defined rate (temperature ramps).
Precise control allows for reproducible testing conditions.
Operation is user-friendly via an integrated touch panel.
Features:
- Fast temperature changes (up to 5 K/min)
- Even temperature distribution in the test space
- Water-cooled system
- Industrial standard – robust construction
- Maintenance indicator and operating hours counter included
Technical Data:
Model: TempEvent T/1000/70/5
Temperature range: approx. -70 °C to +180 °C
Temperature change speed: up to 5 K/min
High precision & stability:
Temporal temperature deviation: ±0.1 to ±0.5 K
→ very stable temperature over time
Spatial deviation: ±0.5 to ±1.0 K
Temperature gradient: ≤ 2.0 K
This makes the chamber ideal for demanding testing processes
with high repeat accuracy.
Test chamber dimensions: approx. 950 × 1100 × 950 mm (W × H × D)
External dimensions: approx. 2000 × 1415 × 2030 mm (W × H × D)
Side port: 50 cm / 125 cm
Electrical data:
400 V / 3~ / 50 Hz
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerants:
R449A (approx. 2.9 kg)
R23 (approx. 1.3 kg)
Weight: approx. 1,200 kg
For your security as a buyer, please note the following:
The following checks are carried out on all our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications subject to change and errors excepted!)
Further questions can be answered for you by phone.
We make it easier for you to find: "testing"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Testing (10,784)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month










































































































































































































































