Used Tensile Test for sale (11,002)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,614 km
Climate test chamber with seat pulsator
WeissSD 1400/+20 DU
Call
Condition: good (used), Weiss Climatic Test Chamber with Seat Pulsator
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test Chamber:
Material: Stainless steel
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Capacity: 1440 liters
Outer casing
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: Light gray (RAL 9002)
Double-leaf door: hinged on the left and right
Equipment:
Tubing in the floor and ceiling: 2 each, NW 100 mm, for installing the pulsator tables
Tubing in the the side walls: 1 each, left and right, 100 mm
Cooling unit: Air-cooled
Control: Digital measurement and control system DMR
Basic control panel: Integrated into the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance data:
Csdpfxsxbgrgo Aaqjhd
Temperature range without air conditioning: +20...+100 °C
Temperature stability without air conditioning: +0.2 ... t0.5 K (over time) depending on the range, in steady state
Temperature range with air conditioning: 20...+95 °C
Temperature stability with air conditioning: +0.2 ... +0.5 K (over time) depending on the range, in steady state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH depending on the range, in steady state
Temperature change rate measured in the exhaust without a test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. On average, between +20 and +100 °C
The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel construction for placing and attaching to the climatic test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for changing test specimens, 12 weights of 5 kg each
• 1 base frame in mild steel welded construction for attaching to the underside of the climatic test chamber. This frame is equipped with removable panels on all sides and has two hinged doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric discs with bearings and tachometer, 2 connecting rods, 2 ball bearings,
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for attaching the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for attaching the buttocks simulation
• 2 stainless steel 60° load rods (The connection to the test specimen is not included in our price, but can be offered subsequently upon precise specification.)
• 2 three-phase motors, 2 belt drives with tensioning devices,
• 1 pneumatic control unit with 2 manual valves, a filter-regulator unit, and a shut-off valve. 1 electrical control cabinet with 2 SEW frequency converters, hand switches, emergency stop button, 2 on/off switches, 2 speed indicators, 2 potentiometers for speed adjustment, 2 pre-selected load changers with zero position and shutdown.
Technical specifications:
Frequency: 100-1000 strokes/minute
Load: 2 x 45 g
Stroke: 0-40 mm
Load from above: 450 N each
You can find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,623 km
Climate test chamber -10°C to +90°C
VötschVC 0018
Call
Condition: used, Vötsch
Model: VC 0018
Climate Test Chamber, Air-Cooled
Test Chamber Dimensions: Width 580 x Depth 450 x Height 750 mm
External Dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test Chamber Volume: approx. 190 liters
Specifications for Temperature Testing:
Temperature Range: -10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.5 K
spatial: ±0.5 to ±2.0 K
Chsdpfow Hz S Uox Aaqed
Temperature Change Rate according to IEC 60068-3-5
Heating: 0.6 K/min
Cooling: 0.3 K/min
Heat compensation in the range +20°C to +50°C: 200 W
Calibration Points: +4°C and +90°C
Specifications for Climate Testing:
Temperature Range: +10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.3 K
spatial: ±0.5 to ±1.0 K
Humidity Range: 10% to 98% RH
Electrical Connection:
Rated Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 1.7 kW
Rated Current: 9.5 A (neutral conductor plug loaded), Schuko approx. connection cable: 3.5 m
Protection: 16 A slow-blow, provided by the customer
Weight: approx. 380 kg net
Refrigerant: R 134A
For your safety as a buyer, please note the following information!
The following points are carried out on all climate chambers we offer prior to delivery:
1. Functional check and replacement of necessary components
2. If necessary, a refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data are subject to change and errors are excepted!)
We are happy to answer any further questions you may have by phone.
Listing
Amstetten
8,329 km
Weiss climate test chamber SB11/300/40 -40..
WEISSSB11/300/40
Call
Year of construction: 1995, condition: excellent (used), functionality: fully functional, machine/vehicle number: SB11/300/40, For sale is a Weiss climate test chamber.
Designation: SB11/300/40
Cooling-heating operation: -40...+180 °C
Climate operation: +10...+95 °C
Humidity range: 10...98 % RH
Temperature stability
The temporal temperature stability in climate mode is ±0.1...±0.5 K
The temporal temperature stability in cooling-heating mode (without climate) is ±0.2...±0.5 K
Humidity stability
The temporal humidity stability across the entire operating range is ±2...±3 %RH
Condenser: air-cooled
Rate of temperature change:
Cooling: approx. 3.1 K/min
Chjdpfjw Dygfjx Aaqsd
Heating: approx. 3 K/min
Test chamber volume: approx. 301 L
Internal dimensions: Height 680 mm, Width 540 mm, Depth 820 mm
External dimensions: Height 1700 mm, Width 800 mm, Depth 1780 mm
Weight: approx. 420 kg / Power supply: 4.8 kVA
Electrical connection: CEE plug 16 A
Connection voltage:
400V/3Ph+N+PE/50 Hz (+6%/-10%)
Refrigerant: R404A!
Version: mobile
Type: SB11/300/40
Listing
Hessisch Lichtenau
7,826 km
Test bench, test station, measuring station, test device, measuring device, tester for HV, PE, IS me
ELABOPE/IS/HV SCT 42 / 91-3J.3 + 90-1V + 90-9B.3ZM92510
Call
Condition: used, Test console, test station, measuring station, test device, measuring instrument, tester for HV, PE, and IS measurements
ELABO Type PE/IS/HV SCT 42 / 91-3J.3 + 90-1V + 90-9B.3ZM92510
High-voltage tester
The PE/IS/HV SCT 42 / 91-3J.3 is used for testing dielectric strength, insulation resistance, and protective earth voltage drop in accordance with VDE0113 or IEC regulations per EN60204, Part 1.
Serial No.: 0064016 Year: 2004
Rated voltage: 230 VAC
Rated frequency: 50 Hz
Rated current: 6.3 A
- Protective earth resistance measurement
- Insulation resistance measurement
- Protective earth voltage drop measurement
The 90-1V unit provides a highly stable DC voltage with low ripple. One output terminal supplies the high voltage, while the other is near earth potential and can be set to a potential of up to 300 V.
Device No.: 90-7WZ006 Year: 2000
Mains voltage: 230 VAC
Mains frequency: 50 Hz
Rated current: 1 A
Interference suppression: according to VDE 0871
Rated power: 14 watts
Output voltage: 0 - 6.0 kV DC
Output current: 0 - 2 mA
Connection unit for ELABO testers, switching matrix, connector unit
ELABO Type 90-9B.3ZM92510
Serial No.: 0097588 Year: 2009
Rated voltage: 230 VAC
Cedpsf Axn Ajfx Aaqehd
Rated frequency: 49 - 61 Hz
Rated current: 1 A
Number of test points: 5
- Compact unit on mobile frame
- Various connection cables and accessories as shown
Overall dimensions (L x W x H): 580 x 700 x 1380 mm
Total weight: 100 kg
Good condition
Many other ELABO devices under stock numbers 57819, 57820, and 57821
Listing
Borken
7,614 km
Weathering test device Test chamber
HeraeusXenotest 1200 CPS
Call
Operating hours: 3,888 h, condition: good (used), Heraeus Xenotest 1200 CPS weathering tester
Xenon device for testing the lightfastness and weather resistance of materials under simulated conditions
Electrical connection
Voltage: 400 V
Nominal current: 50 A max.
Connected load: 33 kVA max.
Chedpfxjxal Hao Aaqsd
Power consumption of xenon lamps: 2.8 - 6 kW per lamp
Compensation: 3 capacitors, 50 uF each
Operating hours: 3888
You can find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
7,623 km
Climate test chamber 1540 liters
WeissWK1-1500/40 Temp. -40°C bis +180°C
Call
Condition: used, Weiss
Type: WK1/1500/40
Weiss Climate Test Chamber, Air-Cooled with Humidity Control
(converted to use refrigerant R-452a)
Temperature range: -40°C to +180°C
Cooling rate approx. 2.5 K/min, heating rate approx. 3.5 K/min
Temporal temperature deviation at center of test space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature range: +10°C to +95°C
Humidity range: 10% to 98% r.H.
Temporal temperature deviation at center of test space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Heat compensation
In the range of +25°C to +95°C, at a relative humidity up to 90%: 500 W
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 1475 mm
External dimensions: Height: 2005 mm, Width: 1300 mm, Depth: 2450 mm
Test volume: approx. 1540 liters
Test chamber lighting: Halogen bulb 12V, 50W
Rated voltage: 3/NPEAC 400V ±10% 50Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Fuse on site: 32A slow-blow
Protection class (control cabinet and operator panel): IP 54
Refrigerant: R-452a
Weight: 920 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and errors excepted!)
Cedsw Hcttepfx Aaqehd
If you have further questions, we will be happy to answer them by phone.
Listing
Hessisch Lichtenau
7,826 km
Test bench, test station, measuring station, test device, measuring device, tester for HV, PE, IS me
ELABOPE/IS/HV / 91-3J.3 + SHV 16 / 90-1V.3 + 90-9B.3ZM9
Call
Condition: used, Test bench, test station, measuring station, test device, measuring device, tester for HV, PE, and IS measurement
ELABO Type PE/IS/HV / 91-3J.3 + SHV 16 / 90-1V.3 + 90-9B.3ZM92510
High voltage test device
The device PE/IS/HV / 91-3J.3 is used for testing dielectric strength, insulation resistance, and protective conductor voltage drop in accordance with VDE0113 or IEC regulations according to EN60204, Part 1.
Serial no.: Year of manufacture: 2003
Rated voltage: 230 VAC
Rated frequency: 50 Hz
Rated current: 6.3 A
- Protective conductor resistance measurement
- Insulation resistance measurement
- Protective conductor voltage drop measurement
The device SHV 16 / 90-1V.3 provides a highly stable DC voltage with minimal ripple.
Chjdped Dc Unefx Aaqsd
One output terminal supplies high voltage, the other output terminal is close to earth potential and can be set to a maximum potential of 300 V.
Serial no.: Year of manufacture: 2005
Mains voltage: 230 VAC
Mains frequency: 50 Hz
Rated current: 1 A
EMI suppression according to VDE 0871
Rated output: 14 watts
Output voltage: 0 - 6.0 kV / DC
Output current: 0 - 2 mA
Connection unit for ELABO tester, switching matrix, connector unit
ELABO Type 90-9B.3ZM92510
Serial no.: 0063475
Rated voltage: 230 VAC
Rated frequency: 49 - 61 Hz
Rated current: 1 A
Number of test points: 5
- Compact unit on roller frame
- Various connection cables and accessories as shown
Overall dimensions (L x W x H): 580 x 700 x 1460 mm
Total weight: 100 kg
Good condition
Many other ELABO devices under stock numbers 57820 and 57821
Listing
Borken
7,614 km
Large-scale climate test chamber
VötschVCZ 04032
Call
Condition: good (used), Large-scale system for climate tests with S!MCON control
Design
The system consists of the following main components:
- Walk-in, insulated test room
- Air treatment room
- Machine unit
- Air conditioning system
- Control cabinet
Test room
The fixtures in the test room are made of corrosion-resistant material.
The test room can be illuminated, is walk-in, and has a condensate and cleaning drain.
Air treatment room
The air treatment room is located behind the air baffle in the insulated interior.
It contains the following components necessary for temperature control and is accessible via easily removable panels.
- Test room fans
- Heat exchangers
- Electric heaters
- Ventilation and exhaust system
- Temperature sensors
In the air treatment room, the air is tempered (cooled/heated), humidified and dehumidified, and circulated by fans.
The air is drawn in under the ceiling and expelled at floor level.
Sensors
The temperature and humidity sensors are located behind the air baffle in the air treatment room.
Machine Unit
The machine unit, consisting of refrigeration units, supplies the air treatment room with the required energy.
Climate System
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Cjdew U Sv Eopfx Aaqohd
Direct temperature range: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5°C
Humidity fluctuation: +/- 3 to +/- 5% RH
Cooling water specifications
Connections
Inlet: 2 x 1 1/2" RH
Return: 2 x 1 1/2" RH
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10,000 N/m²
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m, Height 2.20 m, Depth 5 m
Climate chamber divided for transport at a specified location (approx. 2.50 m).
Find more items – new and used – in our shop!
International shipping costs on request!
Listing
Borken
7,623 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150
Vötsch Temperature Test Chamber, Air-Cooled
Csdpfew Ehutex Aaqohd
Temperature Testing
Temperature Range: -40°C to +180°C
Rate of Change: Cooling approx. 2.5 K/min
Rate of Change: Heating approx. 3.5 K/min
External Dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test Chamber Dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Rated Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Power: 11.5 kW
Rated Current: 22.0 A
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as a buyer, please note the following information:
We perform the following steps on all chambers offered:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: Used
Scope of delivery: (see photo)
(Technical data subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Hessisch Lichtenau
7,826 km
Tensile force measuring device, crane scale with memory and printer for measured values, heavy-duty
MWT142
Call
Condition: used, Electronic crane scale MWT type 142
Make No.: 142571 Year of construction 1993
Tensile force measuring device, crane scale
Measuring range: 2.500 to 80.000 kg
Cjdpfjg D H Riox Aaqehd
Smallest measured value: 20 kg
Power supply via 12 Volt accumulator
- Suspension shackle for double hook, anchor hook
- Operation, storage of measured values and tare via remote control
- Memory for measured values (weights)
- Printer for measured values
very massive and high quality body made of steel
own weight: approx. 200 kg
Listing
Borken
7,614 km
Climate test chamber
EspecPR-3KP
Call
Condition: good (used), operating hours: 75,383 h, Espec PR-3KP Environmental test chamber -20 to +100 °C
Features:
Chodewbz Hhepfx Aaqjd
Manufacturer: Espec
Type: PR-3KP
Temperature range: -20 to +100 °C
Humidity: 20 to 98 % rH
Refrigerant R-404A:- CFC-free - ozone-friendly
Operating hours: 75383
Dimensions:
External dimensions: HxWxD= 1680 x 1050 x 1200 mm
Chamber dimensions: HxWxD= 850 x 600 x 800 mm
Further items in other sizes - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
7,623 km
Climate test chamber with humidity, 306 liters
EspecPSL-2KPH -70°C bis +150°C
Call
Condition: excellent (used), Espec
Type: PSL-2KPH
Chedpew D Dgvsfx Aaqsd
Thermo TEC
Espec Temperature and Climate Test Chamber, Air-Cooled
Temperature range: -70°C to +150°C
Humidity range: 20 to 98% rH
Temperature/Humidity Fluctuations: ± 0.3°C / ± 2.5% rH
Temperature/Humidity Stability: ± 0.5°C / ± 3% rH
Heat-up time: from -70°C to +150°C in 50 min
Cool-down time: from +20°C to -70°C in 80 min
Test chamber dimensions: width 600 mm x height 850 mm x depth 600 mm
External dimensions: width 1010 mm x height 1690 mm x depth 1173 mm
Test chamber volume: 306 liters
Refrigerants: R-404A, R-508A
Stainless steel construction
Connection: AC 400V 3~ 50/60 Hz Max. 18 A
Rated power: 1.5 kW
Net weight approx. 400 kg
For your safety as a buyer, please note the following information!
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New charge with legally compliant refrigerant
3. After successful inspection, the chambers undergo a test run, monitored with calibrated instruments.
Condition: used
Scope of delivery: (see photo)
(Technical data and specifications may be subject to change and errors!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,623 km
Leak test system measuring range ±20 mbar
dr. wiesnerIntegra DDV -1...1 bar
Call
Condition: used, dr. wiesner
Type: INTEGRA DDV -1...1 bar
Product description:
dr. wiesner Integra leak test system
The classic - for all common test procedures
The leak test system for industrial leak-tightness and flow tests
with fully graphical color display
up to three independent test circuits operable
255 test programs can be stored
automatic process optimization autoTune (option)
communication via flexibly exchangeable bus coupling modules
freely programmable fixture control
freely programmable special test procedures
The device is suitable for tests according to the relative and differential pressure method with overpressure.
Special versions: none
Technical data:
Electrical supply: 110 ... 230V~; 50 ... 60Hz (connection via power cable to plug XO)
pneumatic: clean and dry compressed air max. 7 bar (to connection P)
Test pressure range: 0 ... 1000 mbar, electronically regulated
Measuring ranges
Relative pressure: 0 ... 1000 mbar
Differential pressure: +20 mbar
Resolution: 0.1 Pa
Internal volume:
13 cm³ test circuit
15.0 cm³ reference circuit
Chjdpfxewqm Dds Aaqod
Electrical interfaces: 3x serial RS232 (COM1; COM2; COM3)
1x digital I/O (X1)
pneumatic:
Connection test object (Test)
Connection reference circuit (Ref.)
Enclosure
Protection class: IP40
Dimensions: 450x185x380mm (WxHxD)
Weight approx. 15.5kg
Condition: used
(Changes and errors in the technical data, information reserved!)
We are happy to answer further questions by phone.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
VötschVTS 7018-5 190 Liter
Call
Condition: excellent (used), Vötsch
Model: VTS 7018-5
Water-cooled Temperature Test Chamber
System retrofitted with R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10.0 kW, Rated current: 21 A
Main fuse (on-site): 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side port: 50 mm / 125 mm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight approx. 460 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Csdjwq Iymopfx Aaqjhd
Scope of delivery: (See picture)
(Technical data may be subject to change or error!)
If you have any further questions, we will be happy to answer them by phone.
Listing
Borken
7,623 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here we offer shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
Temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Operating hours: 27.903 hrs.
Weight: 1000 kg
For you as a buyer, the following information for your safety!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Chjdpsi Az Egjfx Aaqed
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Type: VT 7012 S2
Water-cooled
Two-chamber design
Hot chamber:
The temperature range of the hot chamber is from +50°C to +220°C.
Temperature deviation over time in the center of the chamber is ± 1 K.
Temperature deviation over space is ± 2 K.
Temperature change rate:
Heating: 11 K/min.
Cold chamber:
The temperature range of the cold chamber is from -80°C to +70°C.
Temperature deviation over time in the center of the chamber is ± 1 K.
Temperature deviation over space is ± 2 K.
Temperature change rate:
Heating: 2 K/min.
Cooling: 3 K/min.
Test chamber volume: 125 liters.
Hot chamber temperature range: +50°C to +220°C.
Cold chamber temperature range: -80°C to +70°C.
Test chamber dimensions: Width: 470 mm. Depth 650mm Height 410mm
External dimensions: Width 930mm Depth 2115mm Height 1970+mm
Plug-in diameter 67mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power 10 kW
Rated current 25 A
Refrigerant R404A / R23
Chodpfxewzilrs Aaqed
Weight: 1000 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Water-Cooled Temperature Test Chamber
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
Chodpfx Ajwyu H Eoaqsd
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
Listing
Borken
7,623 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-10 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-10
Vötsch Climate Test Chamber, Water-cooled
Specifications for Temperature Testing:
- Temperature range: -70°C to +180°C
- Temporal temperature deviation at the center of the usable test volume: ±0.3 to ±0.8 K
- Spatial temperature deviation: ±0.5 to ±2 K
- Temperature gradient: 1 to 4 K
- Temperature change rate:
- Heating: 11 K/min
- Cooling: 10.5 K/min
Specifications for Climatic Testing:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98% RH
Chodpfxswynmxe Aaqod
- Temporal temperature deviation at the center of the usable test volume: ±0.2 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temperature gradient: 1 to 2 K
- Temporal humidity fluctuation at the center of the usable test volume: ±1 to ±3 % RH
Technical Data:
- External dimensions (with hinges and door lock):
- Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
- External dimensions (without hinges and door lock):
- Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
- Internal chamber dimensions:
- Height: 950 mm, Width: 1100 mm, Depth: 950 mm
- Test chamber volume: approx. 1300 liters
Feedthroughs:
- The chamber is equipped with feedthroughs on both the right and left sides, allowing measurement cables and test devices to be routed into the test space.
- 1 x R1 NW 125 mm
- 1 x L1 NW 50 mm
Test Chamber Lighting:
- Halogen bulb 24 V, 50 W
Electrical specifications:
- 3/N/PE AC 400V ±10% 50Hz
- Rated power: 34.0 kW
- Rated current: 50.0 A
- Fuse (to be provided on site): 100 A slow-blow
- Max. heat emission to environment: 2.2 kW
Permissible Test Specimen Weight:
- Total load on grate supports: 100 kg
- Chamber floor: 150 kg; Inserted rack: 50 kg
Refrigerants:
- R 404A / R 23
Weight: 1600 kg
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in technical data and information!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
VötschVT 7021
Call
Condition: excellent (used), Heraeus Vötsch
Type: VT 7021
Air-cooled temperature test chamber
1 port, nominal width 80 mm,
Test chamber volume: 210 liters
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (heating): 2.5 K/min
Chjdjwylv Djpfx Aaqsd
Temperature change rate (cooling): 2.5 K/min
Max. heat compensation: 800 W
Test chamber dimensions: Width 560 mm, Depth 570 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1250 mm, Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50 Hz
Rated power approx. 1.8 kW, rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
For your safety as a buyer, please note the following information!
The following procedures are performed on the chambers we offer, in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors in the details!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,623 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
Chjdpfxswxc I Uj Aaqjd
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Germany
7,623 km
Stress test chamber
EspecEHS-221M
Call
Condition: excellent (used), Espec
Here we offer an Espec(ThermoTec) stress test chamber.
Chjdpon Arznjfx Aaqed
Overpressure humidity tests at over 100 degrees in many different modes
Program capacity of 10 patterns with 30
steps per pattern
A variety of protection mechanisms; overheat/overpressure protection, detection of water-
supply failure.Complete door interlock and temperature sensor.
Saturated Temp Range 105 to 142.9°C
Unsaturated Temp Range 105 to 132.9°C
Humidity range 50 to 100% r.h.
Nominal pressure 0.196 MPa at 132.9°C and 100% e.F.
External dimensions: width 740 x height 1553 x depth 1000 mm
Test chamber dimensions: Width 355x Height 355 x Depth 426 mm
Other equipment:
with rails and grid
Test material connections in the interior
Type: EHS-221M
Scope of delivery: See pictures
300 kg
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,623 km
Temperature test chamber 600 liters
CTST-40/600 -40...180°C
Call
Condition: excellent (used), CTS
Type: T-40/600 /011232
CTS Temperature Test Chamber, Water-Cooled
Includes metal struts to increase the floor load-bearing capacity
Test chamber volume: 600 liters
Test chamber dimensions:
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth approx. 1850 mm
Temperature operating range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K over time
Heating rate: 2.5 K/min
Chodjwfdniopfx Aaqed
Cooling rate: 3 K/min
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Rated power: approx. 5.5 kW
Rated current: approx. 8.5 A
Refrigerant: R-404A
Weight: 550 kg
For your safety, please note the following information!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature test chamber 335 liters
VötschVT 4034 -40°C..+180°C
Call
Condition: excellent (used), Vötsch
Type: VT 4034
Vötsch Temperature Cabinet VT 4034 Air-Cooled
Refrigerant: Converted to R-452 A
Internal dimensions: Height 750 mm, Depth 765 mm, Width 580 mm
External dimensions: Height 1780 mm, Depth 1595 mm, Width 865 mm
Temperature range: -40°C to +180°C
Temperature deviation:
temporal ± 0.1 to ± 0.5 K
spatial ± 0.5 to ± 2.0 K
Heating 3.2 K/min
Cooling 3.5 K/min
Maximum load (evenly distributed across the surface)
of the test chamber floor: 60 kg
per insert: 30 kg
Total load of the grate supports: 80 kg
Test chamber lighting: 24 V halogen bulb 50W
Rated voltage: 3/N/PE AC 400V ± 10% 50 Hz
Rated power: 4.1 kW
Rated current: 12.5 A
Fuse provided by the customer: 16 A slow-blow
Refrigerant: R-452A
Weight: 490 kg / 335 liters
For your safety, the following information!
The following steps are carried out on our chambers in advance:
1. Functional test and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
Cedpewd Hpasfx Aaqohd
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature test chamber
RS-SimulatorenTS 600/45 EX
Call
Condition: excellent (used), RS Simulators
Here we offer a test cabinet.
Water cooled
Temperature range: -40°C to +180°C
Test chamber dimensions: 850mm x 850mm x 800mm (WxHxD)
Outer dimensions: 1100mm x 1850mm x 1500mm (WxHxD)
current consumption: 13,5 A
Refrigerant: R404A
Connection voltage: 3x400V/N/PE 9A
Weight: approx. 750kg
Type: TS 600/45
Csdog Urq Ispfx Aaqohd
Explosion proof operation not tested
but Max 160°C in this
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing
Borken
7,623 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss temperature shock test chamber air cooled
( Compressor was renewed ! )
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot-/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Codpek E Htysfx Aaqshd
Width ( without and with swivel arm ) without....ca. 1820 mm with....ca. 1915 mm
Depth ( without and with test chamber door ) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
We make it easier for you to find: "tensile test"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Tensile Test (11,002)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you