Used material testing for sale (476)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Measuring & testing equipment Material testing
Listing
Borken
7,623 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature cabinet.
Heraeus Vötsch temperature chamber water cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
Outer dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range - 70°C to +180°C
Temperature deviation in time ±0.1 to ±0.5 K
Temperature deviation spatial ±0.5 to ±1.5 K
Temperature gradient 1 to 3 K
Temperature change rate cooling 3.2 K/min
Temperature change rate heating 3,5 K/min
Refrigerant: R-404 A / R 23
Voltage 1/N/PE AC 230V±10% 50Hz
Rated power 1,8 kW
Rated current 12 A
Type: VT 7011
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Bljdpjhrdy Sofx Agloc
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Tensile testing machine Table-top testing machine
Zwick / RoellBDO-FB0.5TH
Call
Condition: excellent (used), Here we offer you a Zwick / Roell tensile testing machine table-top testing machine.Zwick / Roell material testing machine BDO-FB0.5TH load in tensile / compression direction 500 N height 1565 mm , width 292 mm , depth 469 mmwidth of the test surface: infiniteTest range depth: 100 mmMax working stroke w.o. Accessories 1266 mmPC or printer interface RS 232Required PC connection (for PC operation) COM 1Performance data: 115/230 V (PH, N, PE)Rated power : 0.4 kVAN power frequency: 50/60 HzWeight: 47 kgType: BDO-FB0.5THCondition: used / usedScope supplied: (See picture)(Changes and errors in the technical data, details reserved!)We will be happy to answer any further questions you may have on the phone.
Bjdpfx Aod Sr S Ieglslc
Listing
Borken
7,623 km
Vibration test system
RMSSW 1507 / TGA 1500
Call
Condition: excellent (used), RMS vibration exciter with power amplifier and cooling fan
Here we offer you a RMS vibration exciter with power amplifier.
Vibration exciter SW 1507
Blsdpfogkafisx Aglec
Max force 2158 N
max. speed 1,3 ms
Power amplifier TGA 1500
3 x 380V/ 50Hz/ 35A / 8 kVA
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing
Borken
7,623 km
Shaker vibration test machine
RMSSW 3006 mit TGA 3000-000.00
Call
Condition: excellent (used), RMS Vibration test system
Here we offer you a RMS electrodynamic vibration test system.
RMS Vibration Test System
Test Manager SWR 900
Vibration exciter SW 3006
30V-50A-3434 N
power amplifier TGA 3000-000.00
Condition: used / used
Untested! Tests were not possible
Bljdogk I I Tspfx Agljc
Scope of delivery: (See picture)
(Changes and errors in the technical data, data are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing
Borken
7,623 km
Temperature chamber
WEISSWT11-1000/70/5
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer a Weiss temperature chamber.
Weiss temperature chamber air cooled with Weiss condenser cooler
Test chamber capacity approx. 990 liters
Data for temperature tests:
Temperature range -70°C to +180°C
Temperature deviation in time in the center of the chamber ± 0.1 to ± 0.5 K
Temperature deviation spatially ± 0.5 to ± 2.0 K
Temperature gradient (acc. to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 5 K/min
Cooling 5 K/min
Heat compensation max. 2750 W
Feedthrough built into basic equipment
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x depth 950 mm x height 950 mm
Housing dimensions: width 1390 mm x depth 1525 mm x height 1995 mm
maximum load (evenly distributed over the surface) of the test chamber floor 150 kg
per insert grate 50 kg
total load of the grate supports 100 kg
Bledpep Dun Ajfx Agloc
Data for operation:
Test room lighting halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 27,0 kW
Rated current 42,02 A
Heat output water-cooled test chambers max. heat output to environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: ( converted to R-452a )
weight: approx. 960 kg
Type: WT11-1000/70/5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. function check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80 water cooled
Bsdpfsm Tvzcex Agljlc
Cold-heat operation: -75°C ...+180°C
Climatic operation: +10...+95°C
Humidity range: 10...98 % r. h.
Temperature constancy, temporally ± 0.2K
Humidity constancy: ±1 r.F.
Temperature rate of change:
Cooling: approx. 1.4 K/min
Heating up: approx. 2.5 K/min
External dimensions: Height 1980 mm, width 1265 mm, depth 1365 mm
Feedthroughs:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/ 50 Hz
Power: 10,4 kVA
Weight: approx. 720 kg
Refrigerant R404a / R 23
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Air-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Blsdpfx Agjrak S Delec
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climatic chamber
EspecEGNX12-6CWL
Call
Condition: good (used), Espec
Type: EGNX12-6CWL
Espec temperature and climate test chamber air-cooled
Temperature (and humidity) test chamber N series
Bledot Nf Upjpfx Agloc
Power supply:
AC 400/460 V 3-phase 50/60Hz 32A
Temperature range -70 to +180°C
Humidity range 10 to 95% r. H.
Temperature change rate
Heating 15 °K/min
Cooling 11 °K/min
Internal dimensions W x H x D in mm 600 x 750 x 850
External dimensions W x H x D in mm 889 x 2098 x 1768
Useful volume 380 l
Refrigerant R404A
Weight: 370 kg
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate chamber Temp. and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Bljdetzbzcopfx Aglsc
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Maximum current 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climatic test chamber
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate chamber Temp. and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Maximum current 400 VAC 8.3 A
Blsdpfx Aotzbz Aoglec
Weight: 335 kg
Scope of delivery: Espec climatic test chamber
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Bedpfx Ageun Izcolslc
Listing
Borken
7,623 km
Weathering tester
AtlasXenotest Alpha LM
Call
Condition: good (used), Atlas
Blsdpfx Asuuaryjgloc
Type: Xenotest Alpha LM High Energy
Weathering tester
Atlas Xenotest Alpha LM is a universal weathering instrument for testing the lightfastness
and weathering resistance of materials under normal, high temperature and high performance conditions.
XENOCHROME Filter
XENOSENSIV gearbox
Control of lamp power in W/m²
Sample chamber temperature controlled up to 70 degrees
Measuring sensors at sample level XENOSENSIV E(300-400 nm) and SST
Stationary sensor for sample chamber temperature and relative humidity
Humidification
Irrigation
Water supply with integrated water tank
Electronic version: 230V, 50/60Hz
Absorption filter 7 IR: Synchronization 40 - 140 W/m² Coil run 21 - 72 W/m²
Window glass 10 FG: Synchronization 40 - 110 W/m² Coil run 21 - 57 W/m²
Absorption filter 4 IR + 3 window glass: Synchronization 40 - 140 W/m² Coil run 21 - 72 W/m²
Absorption filter 6 IR + 1 UV: Synchronization 40 - 140 W/m² Coil run 21 - 72 W/m²
Rel. electrical power without XENOSENSIV sensor: continuously regulated to the set value 53 - 120 %
Sample chamber temperature: 20 - 70° (depending on selected filter configuration)
Black standard temperature: synchronized 25 - 130 °C coiled 25 - 100 °C
Relative humidity: 10 % - 95 %
Fan revolutions: 500 - 2500 rpm
Dimensions: 900 x 780 x 1800 mm
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate cell
TiraTTZ 4008
Call
Condition: good (used), TIRA
Type: Walk-in climate simulation cell TTZ 4008 S(m)
Technical data:
Temperature range -40...+120 °C
Temperature tolerance: +/- 1.0°C
Temperature change rate: 1 K/min
Humidity range
10...approx. 95 % r.h.
Humidity tolerance
+/- 5.0 % r.h.
Dimensions:
Test chamber volume: 8m³
External dimensions (WxDxH) approx. 2410mm X 3920mm X 2530mm
Test chamber (WxDxH) approx. 2002mm Χ 2148mm Χ 2005mm
Door opening (WxH) approx. 2002mm X 2005mm
Condition: gebraucht / used
Bsdpfx Agouvil Selolc
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate cell
RS-SimulatorenKKC 22/45
Call
Condition: good (used), RS Simulators
Type: Walk-in climate simulation cell KKC 22/45
Technical data:
Temperature range -40...+120 °C
Temperature tolerance: +/- 1.5°C
Temperature change rate: 1 K/min
Humidity range
10...approx. 95 % r.h.
Humidity tolerance
+/- 5.0 % r.h.
Dimensions:
Test chamber volume: 22m³
External dimensions (WxDxH) approx. 2600mm X 6400mm X 2800mm
Test chamber (WxDxH) approx. 2200mm Χ 4700mm Χ 2300mm
Door opening (WxH) approx. 2200mm X 2300mm
Blsdouviydspfx Aglsc
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate cell
RS-SimulatorenKKC 22/45L
Call
Condition: good (used), RS Simulators
Type: Walk-in climate simulation cell KKC 22/45L
Technical data:
Temperature range -40...+120 °C
Temperature tolerance: +/- 1.5°C
Temperature change rate: 1 K/min
Humidity range
10...approx. 95 % r.h.
Humidity tolerance
+/- 5.0 % r.h.
Dimensions:
Test chamber volume: 22m³
External dimensions (WxDxH) approx. 2600mm X 6400mm X 2800mm
Test chamber (WxDxH) approx. 2200mm Χ 4700mm Χ 2300mm
Door opening (WxH) approx. 2200mm X 2300mm
Year of construction: 2009
Bledpeuvi Nfjfx Agloc
Technical data Sun simulation:
Control insert: Mitronic STB1-8
Number of lights: 8
Ballast: Mitronic CP2k5 - 2ZS
Ignitor: Hönle
Light source: OSRAM Powerstar HQI 2000W W/D/S
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Blsdpfx Aov N Hc Esglsc
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Electrodynamic testing machine
Zwick/RoellLTM10
Call
Condition: used, Zwick / Roell
Type: LTM10
Max test frequency: 100 Hz depending on the amplitude
Dynamic test force in tension/compression: 10 kN
Static test force in tension/compression: 7 kN
Piston stroke: 60 mm
Positioning and repeat accuracy: +/- 2 µm
Speed range: 1 mm/min - 1 m/s
Test chamber height without force transducer: 1170 mm
Weight with linear motor: 1065 kg (without control unit)
Maintenance: according to maintenance specifications, partly by Zwick/Roell
Accessories: screw clamps, software (TestXpert research)
Connection 400V 50/60 Hz 32A 3Ph/PE
Condition: used
Scope of delivery: (see picture)
Bljdpfxov Ifgtj Aglec
(Changes and errors in the technical data, information are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature chamber TPK 200 280 liters
FeutronTyp: 3416/17 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a temperature test chamber.
Feutron temperature test chamber air-cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: width 1540 mm x height 2090 mm x depth 1240 mm
Fan motor and door removed: Width 1540 mm x height 1940 mm x depth 925 mm
Test chamber: Width 720 mm x height 690 mm x depth 560 mm
Door, clear width: width 720 mm x height 690 mm
Viewing window, heated: width 500 mm x height 600 mm
Installation dimensions of the temperature test chamber with open doors
Width 2340 mm x height 2090 mm x depth 2165 mm
Feed-through opening 2 side panels, left ∅ 100 mm
Bledoqxavaopfx Agljc
Temperature range
-70°C to +180°C
Heating: 3.0 K /min
Cooling: 3.0 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Weight: 635 kg
Type: 3416/17
Refrigerant: R507 / R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
With humidity 270 liters
VötschKlimaprüfschrank VCS³ 7027-10
Call
Condition: excellent (used), Vötsch
Type: VCS³ 7027-10
Vötsch Climatic Test Chamber, Water-Cooled
With a temperature change rate of 10 K/min
Temperature test data:
Temperature range -72°C to +180°C
Temperature deviation over time in the center of the work space ± 0.3 K to ± 0.5 K
Temperature deviation over space ± 0.5 K to ± 2.0 K
Temperature change rate
Heating: 10 K/min
Cooling: 14.5 K/min
Climatic test data:
Temperature range +10°C to +95°C
Bjdpjv R Ty Tsfx Aglelc
(Extended climatic range: 2°C/95% RH, controlled for a maximum of 2 hours)
Temperature deviation over time in the center of the work space ± 0.2 K to ± 0.3 K
Temperature deviation over space ± 0.5 K to ± 1.0 K
Humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening 50 mm
Side opening 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V±10%, 50 Hz
Rated power: 14 kW
Rated current: 26 A
Fuse, on-site: 63 A slow-blow
Refrigerant R404A/R-23
Weight approx. 835 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate cabinet 335 liters
WeissWK-340/70 -70 °C bis +180 °C
Call
Condition: excellent (used), White
Type: WK-340/70
Air-cooled
Test chamber capacity: approx. 335 liters
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
Bedpfx Agsv Uap Njlolc
External dimensions: Height 1805 mm, Width 780 mm, Depth 1700 mm
Characteristics for temperature tests:
Temperature range -70 to +180°C
Temperature fluctuation over time: ± 0.1 to ± 0.5 K
Temperature fluctuation over space: ± 0.5 to ± 2.0 K
Temperature change rate for heating: 3 K/min
Temperature change rate for cooling: 2 K/min
Characteristics for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature fluctuation over time: ± 0.1 to ± 0.3 K
spatial ± 0.5 to ± 1 K
Humidity fluctuation in the center of the usable space ± 1 to ± 3% RH
Electrical connection: 3/N/PE AC, 400 V ± 10%, 50 Hz
Connected load: approx. 4.1 kW
Rated current: 14.0 A
Sound pressure level: approx. 60 dB(A)
Weight: approx. 500 kg
Refrigerant: R404A / R23
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful testing, the chambers are subjected to a test run monitored by calibrated devices.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Stress test chamber
Espec (ThermoTec)TPC-212D
Call
Condition: excellent (used), Espec
Type: TPC-212D
Technical Specifications
Test Procedure: HAST – Highly Accelerated Stress Test
Model: Espec TPC-212D
Internal Volume: 2x (approx. 22 liters)
Internal Dimensions (ø x L mm): 2x 295 x 330 mm
Temperature Range: +105 °C to +142.9 °C
Humidity Range: 75% to 100% RH
Pressure Range: 0.02 to 0.196 MPa gauge (0 to 28 psig)
Power Supply: 220 V (±5%), 1-Phase, 50/60 Hz, 20 A
Special Features: Two chambers in one device
Notes:
Two chambers: Allow for simultaneous tests with different parameters or larger test volumes.
HAST test: Accelerated endurance test under high temperature and humidity
with overpressure for the qualification of electronic components.
Applications: Ideal for semiconductors, ICs, circuit boards, MEMS, etc.
Weight: 230 kg
Condition: Used
Scope of delivery: (See image)
Blodpfx Aowl D Aaoglec
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,623 km
Test chamber for parametric test
S & A-55°C bis +200°C 4365A
Call
Condition: good (used), Here we offer you a S & A test chamber for parametric testing.
Temperature range
-55 ° C to 200 ° C (LCO2)
-65 ° C to 200 ° C (LN2)
Temperature change rate
15° C / min (Standard Option)
60° C / min (Fast Option)
Stability
± 0.2 ° C (including effects of mains voltage, ambient temperature between
between 15° and 45° C and aging)
Uniformity
± 1.0 ° C Max from -65 ° C to -55 ° C
± 0.5 ° C Max from -55 ° C to + 125 ° C
± 1,0 ° C Max from + 125 ° C to + 200 º C
Coolant: LCO2
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 61 kg
Bodpfxecnic Ds Agljlc
Type: 4365A
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, details are reserved!)
Further questions we can answer gladly on the phone for you.
Listing
Borken
7,623 km
Oven
VötschNTU 60/60
Call
Year of construction: 1996, condition: good (used), Here we offer a Voetsch drying oven Waermeschrank Waermeofen.
Voetsch NTU 60/60 250°C
Nominal temperature: 250°C
Supply voltage:
400 V 3 (N) PE AC, 50/60 Hz
Interior dimensions: width 600 mm/height 600 mm/depth 600 mm
External dimensions: width 1000 mm/height 1675 mm/depth 1300 mm
Air circulation blower
Bljdpfx Agebqh I Soljc
Type: Voetsch NTU 60/60
Scope of delivery: (see picture)
(Changes and errors in the technical data are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Electrodynamic shaker
TIRATIRAvib S595/RIT-340
Call
Condition: good (used), Tira
Type: TIRAvib S595/RIT-340
TIRA TIRAvib S595/RIT-340 – Electrodynamic Vibration System (Shaker) with RIT-340 Isolation Frame
For sale is a professional electrodynamic shaker from TIRA GmbH.
The TIRAvib S595/RIT-340 model is designed for highly demanding vibration and shock tests and is operated in conjunction with the TIRAvib A 54336 power amplifier.
The device complies with ISO 5344 and is ideally suited for research institutions, universities, and industry applications (automotive, aerospace, electronics testing).
Technical data:
Performance:
Rated force (SINE): 20,000 N
Rated force (NOISE): 20,000 N
Rated force (SHOCK): 40,000 N
Frequency range: DC – 3 kHz
Resonance frequency of moving system: > 2.4 kHz
Dynamics:
Maximum acceleration:
SINE: 82 g
RANDOM: 82 g
SHOCK: 163 g
Displacement (peak-to-peak): 50.8 mm
Vibration velocity:
SINE: 1.8 m/s
RANDOM: 1.8 m/s
SHOCK: 2.5 m/s
Mechanics
Vibration system mass: 23.9 kg
Load: 410 kg
Spring stiffness: 150 N/mm
Mounting table diameter: 340 mm (24x M10 threaded inserts, bolt circles 100/200/300 mm)
Guidance: 8 spring arms, linear guide (ball bearing)
Stiffness:
Axial: 15 kN/m
Radial: 2,000 kN/m
Torsion: 25 kNm/rad
Max. specimen weight (vertical): 410 kg
Electrical:
Rated current (coil): 200 A
D.C. resistance: 0.084 Ohm
Field coil:
Rated current: 85 A
Rated voltage: 70 V
Resistance at 20°C: 0.75 Ohm
Magnetic stray field (150 mm above table):
without demagnetization coil: < 10 mT
with demagnetization coil: < 1 mT
Demagnetization coil (optional): 36 V / 4 A
Utilities
Cooling performance: 3,300 m³/h air
Compressed air: 600 kPa, oil-free and dry
Power supply: 3P/N/PE – 400 V – 50 Hz
Blodpoxbqr Rofx Aglec
Power consumption: 25 kW
Rated current: 37 A
Dimensions & Weight
Width: 947 mm
Length: 850 mm
Height (vertical): 1077 mm
Total weight (complete frame): 1610 kg
Shaker weight: approx. 900 kg
Condition: used
Scope of delivery: (see picture)
TIRAvib S595/RIT-340 shaker
RIT-340 rotation isolation frame
(Specifications and technical data are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,623 km
Climate test chamber with humidity, 335 liters
VötschVC 7034 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Bedpfoxugirox Aglslc
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used material testing (476)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you