Used Feutron Climate Chamber for sale (5,760)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Climatic chamber with humidity, 335 liters
VötschVC³ 7034 -70°C bis +180°C
Call
Condition: excellent (used), Type: VC³ 7034
Heraeus Vötsch Climate Test Chamber with Humidity Control (Air-Cooled)
Test Chamber Dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
External Dimensions: Width 780 mm x Depth 1,758 mm x Height 1,800 mm
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temporal deviation: ± 0.1 to ± 0.5 K
Spatial deviation: ± 0.5 to ± 1.5 K
Temperature change rate according to IEC 60068-3-5
Heating: 3.0 K/min
Cooling: 3.0 K/min
Specifications for Climate Testing:
Temperature range: -70°C to +180°C
Temperature deviation in steady-state condition, according to IEC 60068-3-5
(depending on chamber temperature)
Temporal deviation: ± 0.1 to ± 0.3 K
Spatial deviation: ± 0.5 to ± 1 K
Humidity range: 10% to 98% RH
Electrical Connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 4.9 kW
Rated current: 16 A
Protection: 16 A slow-blow fuse, provided by customer
Refrigerant: R-404A/R23
Test chamber volume: approx. 335 liters
Net weight: approx. 515 kg
Bwsdpexfh Spofx Afpsh
For your safety as a buyer, please note the following information:
The following actions are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, chambers undergo a documented test run.
Condition: Used
Scope of delivery: (see picture)
(Subject to modifications and errors in technical data and specifications!)
For further inquiries, please feel free to contact us by phone.
Listing
Borken
7,623 km
Climate chamber -75°C / +180°C with humidity
TIRATCC 7120
Call
Condition: excellent (used), TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space) ±0.1°C ... ±0.3 °C
Maximum temperature change rate
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% ÷ ±3%
Dew point range for long-term tests +2 / +94 °C
Bwjdpfx Afewfddwopjh
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x D x H) 1320 x 2235 x 2137 mm
Test space dimensions (L x D x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per grid: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerants: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Salt spray chamber / climate cycling device
WeissSC/KWT 450
Call
Condition: excellent (used), Weiss
Type: SC/KWT 450
Salt Spray Chamber
Technical Data:
Test chamber volume: 450 liters
Maximum load: 100 kg
Brine reservoir: 180 liters
External dimensions: Height 920 mm, Width 1930 mm, Depth 800 mm
Test chamber dimensions: Height 740 mm, Width 850 mm, Depth 570 mm
Applications:
Corrosion tests:
Salt spray test: Ambient temperature up to +50°C
Condensation water test: Ambient temperature up to +45°C
Humidifier +75°C
Temperature stability
The temporal temperature deviation is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 2.0 kW Rated current: 8.5 A
Combination:
Salt spray test SS: DIN 50021
Condensation water test KFW: DIN 50017
Standard climate (ventilation): DIN 50014
Weight: 180 kg
Condition: used
Bwedpfxow Hz Trs Afpjh
Scope of delivery: (See picture)
(Subject to technical modifications and errors! All provided data are subject to change!)
For further questions, please feel free to contact us by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,623 km
Climatic chamber
VötschVCS 7034-5
Call
Condition: used, Vötsch
Model: VCS 7034-5
Climatic Test Chamber, Water-Cooled
Test chamber volume: 335 liters
Specifications for temperature testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: K ±0.1 to ±0.5
Spatial temperature deviation: K ±0.5 to ±2.0
Temperature gradient: 1 to 4 K
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Bedpoxqzbbofx Afpewh
Specifications for climate testing:
Temperature range: +10 to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R404A / R-23
For your safety as a buyer, please take note of the following information!
The following procedures are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and error)
If you have further questions, we would be happy to answer them by phone.
Listing
Borken
7,623 km
Climatic chamber
EspecEGNX12-6CWL
Call
Condition: good (used), Espec
Type: EGNX12-6CWL
Espec temperature and climate test chamber air-cooled
Temperature (and humidity) test chamber N series
Power supply:
AC 400/460 V 3-phase 50/60Hz 32A
Temperature range -70 to +180°C
Humidity range 10 to 95% r. H.
Temperature change rate
Heating 15 °K/min
Cooling 11 °K/min
Internal dimensions W x H x D in mm 600 x 750 x 850
External dimensions W x H x D in mm 889 x 2098 x 1768
Useful volume 380 l
Bsdpst Nf Upofx Afpowh
Refrigerant R404A
Weight: 370 kg
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Discover more used machines
Listing
Borken
7,623 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80 water cooled
Cold-heat operation: -75°C ...+180°C
Climatic operation: +10...+95°C
Humidity range: 10...98 % r. h.
Temperature constancy, temporally ± 0.2K
Humidity constancy: ±1 r.F.
Temperature rate of change:
Cooling: approx. 1.4 K/min
Heating up: approx. 2.5 K/min
External dimensions: Height 1980 mm, width 1265 mm, depth 1365 mm
Feedthroughs:
left side: ∅ 100 mm
Bodpfx Aom Tvzcsfpewh
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/ 50 Hz
Power: 10,4 kVA
Weight: approx. 720 kg
Refrigerant R404a / R 23
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), Here we offer a climatic test chamber.
Air cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
Bjdpfx Asiz Tqcsfpjwh
+5 to +100 C
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Bwedpfx Afov N Hc Ejpeh
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate chamber Temp. and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Bwedpfxotzbzce Afpsh
Maximum current 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climatic test chamber
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate chamber Temp. and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Maximum current 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climatic test chamber
The following information is for your safety as a buyer!
Bwsdpfx Aotzbz Asfpjh
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate test chamber with humidity, 335 liters
VötschVC 7034 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Bwodpfx Afsxugirjpoh
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate test chamber 1000 liters
CTSC-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Climate test chamber C-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% RH
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type C -55/1000/Li
1) C means: climate
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
Climate tests:
Temperature range +5 °C to +95 °C
Humidity range 5% to 95% rel. humidity
Dew point range +5°C to 78°C
Temperature deviation ≤ ±1.0 K in time
Humidity deviation ≤ ±3.0% relative humidity over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may influence the performance data.
Dimensions:
Bodpfx Afova Hi Hopowh
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climatic chamber
VötschVCS 7033
Call
Condition: excellent (used), Heraeus Vötsch climatic chamber
Here we offer you a Heraeus Vötsch climatic chamber.
Vötsch climatic chamber VCS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature change rate:
Heating 7.5 K/min.
Cooling 6,5 K/min.
Bwedopz H Hxspfx Afpoh
Humidity range: 10% to 98% r.H.
Temperature deviation temporal ± 0.5 K
Temperature deviation time-related ± 1.5 K
Test chamber dimensions: Width 675 mm x Depth 650 mm x Height 760 mm
Housing dimensions: Width 930 mm x depth 1565 mm x height 1840 mm
Lateral feedthrough 90mm ∅
approx. 330 L Weight: 600 kg
voltage: 3/N/PE AC 400V ±6/-10% 50Hz
rated power 9,5 kW
Rated current 17 A
Refrigerant R404A / R23
Type: VCS 7033
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climate test chamber Temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate chamber water-cooled
(test room explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST ROOM
Technical data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Test room capacity: approx. 600 liters
Cold / heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98% r. H.
Temperature change per time
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
On-site fuse: 32 A slow-blow
Permissible test item weight
Bodpfx Aev Ewy Hefpowh
Total load of the grate supports 80 kg
Test room floor 80 kg, grate insert 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The air conditioning system's evaporator has been replaced)
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate test chamber with humidity 34 liters
VötschVCL 7003 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Bodpjv Tnd Sofx Afpowh
Type: VCL 7003
Air-cooled climatic test chamber
Test chamber capacity approx. 34 liters
Capacity for temperature tests:
Temperature range -70 to +180°C
Temperature deviation over time ±0.3 to ±1.0 K
Temperature homogeneity over space ±0.5 to ±2.0 K
Heating rate of change 4.0 K/min
Cooling rate of change 3.0 K/min
Heat compensation max. 550 W
Temperature calibration value +23°C and +80°C
Capacity for climatic tests:
Temperature range +10 to +95°C
Humidity range 10 to 98%
Humidity deviation over time ±1 to ±3%
Temperature deviation over time ±0.3 to ±0.5 K
Spatial temperature homogeneity ±0.5 to ±1.5 K
Climate calibration values +23 °C / 50% RH and +95 °C / 50% RH
Test room dimensions: Width 350 mm, Depth 300 mm, Height 310 mm
External dimensions: Width 640 mm, Depth 750 mm, Height 1730 mm
Electrical connection:
1/N/PE AC 230 V ±10%, 50 Hz
Rated current 11.0 A
Rated power, max. 2.5 kW
Sound pressure level 59 dB(A)
Refrigerant: R-404 A / R23
Weight approx. 130 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate test chamber 900 liters
CTSCS-70/900 -70...+180°C
Call
Condition: used, Type: CS-70/900
CTS Climate Test Chamber with Humidity, water-cooled
(converted to R-452a refrigerant)
Bjdpfx Ajxb Dm Iefpowh
Temperature range: -70°C to +180°C
Humidity range: 10–98% RH
Test chamber internal dimensions: Height approx. 870 mm / Width approx. 1000 mm / Depth approx. 1000 mm
External dimensions: Height approx. 1950 mm / Width approx. 1200 mm / Depth approx. 2220 mm
Control cabinet dimensions: Height approx. 2100 mm / Width approx. 800 mm / Depth approx. 400 mm
Test chamber volume: 900 liters
Refrigerant: R-452a / R23
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Connected load: 21.2 kW, Rated current: 35.7 A
Chamber weight: 900 kg
Control cabinet weight: 150 kg
Important safety information for buyers:
The following steps are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
For any further questions, please contact us by phone.
Listing
Borken
7,623 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Bodpfx Asw I Rxrefpowh
Weight: approx. 2,100 kg
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Battery test system with climate chamber
Keysight / Scienlab / AngelantoniBatterie-Testsystem SL1001A
Call
Condition: used, Keysight / Scienlab Battery Test System SL1001A + Angelantoni Climate Chamber DM500 C 10 ESS SPEEDY BT SP
Complete Battery Testing System – For Laboratory Use
Incl. PC, software & technical documentation
For sale is a professional battery test system, consisting of:
- Keysight / Scienlab SL1001A Battery Test System
- Angelantoni DM500 C 10 ESS SPEEDY BT SP Climate Chamber
- Monitoring/Sampling Unit
- Control PC with original software
- Technical documentation
The system is fully functional, well-maintained, and ideally suited for battery module testing, research, development, and quality assurance.
Technical Data – Scienlab SL1001A:
- Manufacturer: Keysight / Scienlab
- Model: SL1001A
- Year of manufacture: 2020
- Voltage / Current / Power: 80 V / 600 A / 24 kW
- Dimensions (L×W×H): approx. 1.6 × 0.9 × 3.3 m
- Weight: approx. 700 kg
- Function: Charging, discharging, and cycling of battery modules
- Condition: Very well maintained, laboratory use only
Technical Data – Angelantoni DM500 C 10 ESS SPEEDY BT SP:
- Manufacturer: Angelantoni Industrie S.r.l., Italy
- Model: DM500 C 10 ESS SPEEDY BT SP
- Year of manufacture: 2019
- Weight: approx. 1,225 kg
- Temperature range: -70 °C ... +180 °C
- Humidity range: 10 ... 98 % rH
- Refrigerants: R449A + R23
- Pressure ranges (PS Hi/Lo): 28 bar / 8 bar
- Wi-Fi integrated
- CE certification present
- Internal dimensions (L×W×H): approx. 1.6 × 2.3 × 3.3 m
- Function: Temperature and humidity testing, ESS (Environmental Stress Screening)
- Power supply: 3PH + N + PE, 400 V ±10 %, 50 Hz, full load 54 A
- Max. power consumption: 32.5 kW
Monitoring / Sampling Unit:
- Dimensions: 0.6 × 0.5 × 0.2 m
- Measured variables: Cell voltages, current, temperature
- Interfaces: CAN, Ethernet
- Compatible with Scienlab / Keysight PathWave software
PC + Software + Documentation:
- Industrial PC with control and measurement software
- Enables automated test runs, logging, and data analysis
Overall Dimensions / Weight (approx.):
Component Dimensions (L×W×H) Weight
Scienlab SL1001A 1.6 × 0.9 × 3.3 m 700 kg
Angelantoni Chamber 1.6 × 2.3 × 3.3 m 1,225 kg
Monitoring / PC 0.6 × 0.5 × 0.2 m 50 kg
Total system L 3.2 m × W 2.5 m × H 3.3 m approx. 1,975 kg
Applications:
- Development, testing, and lifespan analysis of battery modules (e.g., Li-ion, LFP, NMC)
- Fast charging and cycle tests
- Environmental simulation for temperature and humidity
- Research, industrial, and university laboratories
Important Note:
"The table shown in the photos is not included in the sale."
Scope of Delivery:
- Scienlab SL1001A power unit
- Angelantoni DM500 C 10 ESS SPEEDY BT SP climate chamber
- Monitoring/Sampling unit
- Control PC with software
- Technical documentation and manuals
- Connection cables and accessories (as available)
Bedpfexuqk Hjx Afpswh
Condition: used
Scope of delivery: (see image)
(Specifications and data are subject to change and error!)
For any further questions, we are happy to assist you by phone.
Listing
Borken
7,623 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Bwodowgaykopfx Afpeh
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climatic test chamber 800 L, -55°C to +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
Call
Year of construction: 2020, condition: excellent (used), Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
Bwsdow R Rt Ijpfx Afpoh
For further questions, we are happy to answer your call.
Listing
Borken
7,623 km
Salt spray chamber / climate cycling device
WeissSC/KWT 450
Call
Condition: excellent (used), White
Type: SC/KWT 450
Salt Spray Chamber
Technical Specifications:
Test chamber capacity: 450 liters
Max. load: 100 kg
Brine storage tank: 180 liters
External dimensions: Height 920 mm, Width 1930 mm, Depth 800 mm
Test chamber dimensions: Height 740 mm, Width 850 mm, Depth 570 mm
Areas of application:
Corrosion tests:
Salt spray test: Room temperature up to +50°C
Condensation test: Room temperature Up to +45°C
Humidifier +75°C
Temperature stability
The temperature deviation over time is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power 2.0 kW, Rated current 8.7 A
Combination:
Salt spray test SS: DIN 50021
Condensation test KFW: DIN 50017
Normal climate (ventilation): DIN 50014
Bwedpfx Ajw Strcofpsh
Weight: 180 kg
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,623 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation in time K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
Bjdpfxouxq T Ds Afpowh
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climatic test chamber
Technical data:
Test chamber nominal volume 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width 2970 mm Height 2370 mm Depth 1530 mm
Rear wall
Minimum insertion dimensions: Width 2970 mm Height 2390 mm Depth 1550 mm
Test chamber: Width 2000 mm Height 1000 mm Depth 1000 mm
Double-leaf door, clear width Width 2000 mm Height 1000 mm
Heated viewing window, 2 pieces Width 500 mm Height 600 mm
Feed-through opening, 1 side panel left ∅ 75 mm
Temperature range: -40...100°C
Climatic range: 10...95°C
Temperature difference, temporal ≤ ± 0.5...± 1.0 ΔN/K
Change rates measured in the supply air without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 %r. F.
Humidity difference, temporal ≤ ± 3.0 %r. F.
Bodpfxek E Hnqe Afpjwh
Dew point range, temporary down to -5... 95°C
Refrigeration system: water-cooled semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Air conditioning and dryer refrigeration system air-cooled /hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical mains connection: 400V 3/N/PE.AC,50Hz
Mains plug: CEE 5-роlig, 32 A, with 5.0 m cable
Max. simultaneous power requirement 10.0 kW
Supply line fuse: 3x 25, Char, C A
Degree of protection IP20
Weight: 1300 kg
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climatic chamber
RS-Simulatoren
Call
Condition: excellent (used), RS Simulators
Here we offer a climatic test chamber.
Water cooled
300 liters
Temperature range from -75 °C to +180 °C
Time deviation +- 0.2 K to +- 0.8 K
Average heating rate: approx. 2.1 K/min
Average cooling rate: approx. 1.2 K/min
Humidity range from 10 % to 98 % rel. humidity
Working climate range
Temperature: 10 °C to 95 °C
Humidity: 25 % to 75 % relative humidity
Bsdpeiivgvofx Afpjwh
Dimensions: Width 1000 mm 1800 Height mm 1400 Depth mm
Voltage: 3x400V/N/PE Current: 40A
Refrigerant: R404a / R23
Type: KS 300 / 75
Weight: 630 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See pictures)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climate chamber
WEISSWK1-1000/70
Call
Condition: good (used), White
Type: WK1-1000/70
Weiss climatic test chamber water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered by simply touching the function icons on the
all control and operating commands by simply touching the function icons.
Feedthroughs
The test chamber is equipped with feed-throughs on the right and left side.
Measurement cables and test equipment can be routed into the test chamber through these.
Feed-throughs:
1 feed-through ∅ 125 mm installed on the right
1 feed-through ∅ 50 mm installed on the left
Volume 990 liters
Test chamber dimensions:
Test chamber: width 1100 mm, depth 950 mm, height 950 mm
Housing: width 1385 mm, depth 1850 mm, 1980 mm
Bwjdpfxervx Ezo Afpeh
Data for temperature tests:
Minimum temperature -70 °C
Maximum temperature +180 °C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 2 K
Temperature change rate, heating 4 K/min
Temperature change rate, cooling 2.5 K/min
Max. heat compensation 2750 W
Data for climate tests:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ± 1 K
Humidity deviation, temporal ± 1 to ± 3% r.h.
Data for operation:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 29A Nominal power 19.8 kW
Refrigerant: R-452A/ R23
Weight approx. 910kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "feutron climate chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Feutron Climate Chamber (5,760)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month