Used Temperature Test Chamber for sale (17,509)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Climatic test chamber 800 L, -55°C to +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
Call
Year of construction: 2020, condition: excellent (used), Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
Bwjdpfx Aow R Rt Ieaqjw
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
Listing
Borken
7,614 km
Air-cooled climatic test chamber
VötschVC 0033
Call
Condition: good (used), Climatic Test Chamber +10°C to +90°C, Air-Cooled
The test chamber is designed and built for climatic testing within its operating range.
Test procedures that determine the influence of temperature and humidity on material properties
and functional reliability of the test specimen can be performed.
The test chamber can be operated in manual mode (fixed-value mode) or automatic mode.
The EDIT program can be used to program extensive climatic tests and save a maximum of 99 test programs.
These test programs are run in automatic mode.
The test chamber can be controlled during operation via the RS 232 interface with a computer and the TSI software or in ASCII mode.
The operating temperature limiter protects the test specimen from excessively high temperatures.
To protect the test specimen, the upper and lower temperature limits can also be set on the terminal.
Manufacturer: Heraeus Vötsch
Type: VC 0033
Specifications for temperature tests:
Temperature range: +10°C to +90°C
Humidity range: 30 - 95%
Rated voltage: 230V +6/-10% 1/N 50Hz
Bwsdpsxbnkwjfx Aaqjw
Rated power: 2.7 kW
Rated current: 12 A
Refrigerant: R 404A
Test chamber volume: approx. 333 liters
Humidity range:
Humidity range for normal operation (ranges 1 and 3) with a dew point limitation of +5°C
Humidity range 3 is omitted if additionally equipped with a capacitive humidity measurement system
Tolerances for standard climate conditions
23°C/65% RH
Temperature ±0.1 K
Humidity < ±1.5%
85°C / 85% RH
Temperature ±0.1 K
Humidity
Listing
Amstetten
8,329 km
Weiss climate test chamber SB11/300/40 -40..
WEISSSB11/300/40
Call
Year of construction: 1995, condition: excellent (used), functionality: fully functional, machine/vehicle number: SB11/300/40, For sale is a Weiss climate test chamber.
Designation: SB11/300/40
Bwedpfx Aasw Dygfjqsw
Cooling-heating operation: -40...+180 °C
Climate operation: +10...+95 °C
Humidity range: 10...98 % RH
Temperature stability
The temporal temperature stability in climate mode is ±0.1...±0.5 K
The temporal temperature stability in cooling-heating mode (without climate) is ±0.2...±0.5 K
Humidity stability
The temporal humidity stability across the entire operating range is ±2...±3 %RH
Condenser: air-cooled
Rate of temperature change:
Cooling: approx. 3.1 K/min
Heating: approx. 3 K/min
Test chamber volume: approx. 301 L
Internal dimensions: Height 680 mm, Width 540 mm, Depth 820 mm
External dimensions: Height 1700 mm, Width 800 mm, Depth 1780 mm
Weight: approx. 420 kg / Power supply: 4.8 kVA
Electrical connection: CEE plug 16 A
Connection voltage:
400V/3Ph+N+PE/50 Hz (+6%/-10%)
Refrigerant: R404A!
Version: mobile
Type: SB11/300/40
Listing
Borken
7,623 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Temperature Test Data:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Climate Test Data:
Bwsdpfowvgwbox Aaqsw
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at center of workspace: ±1 to ±3% RH
Maximum heat compensation: 8000 W
Enclosure dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides. These allow for test leads and testing devices to be routed into the chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber illumination:
Halogen bulb 24V, 50W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Customer-provided fuse: 100 A slow-blow
Maximum heat output to the environment: 2.2 kW
Permissible test item weight:
Total load on shelf supports: 100 kg
Test chamber floor: 150 kg, Removable shelf: 50 kg
Refrigerants: R 404A/R 23
Weight: 1900 kg
For your security as a buyer, please note:
The following steps are carried out in advance on our chambers offered for sale:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer any further questions by phone.
Listing
Borken
7,614 km
Climate test chamber with seat pulsator
WeissSD 1400/+20 DU
Call
Condition: good (used), Weiss Climatic Test Chamber with Seat Pulsator
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test Chamber:
Material: Stainless steel
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Capacity: 1440 liters
Outer casing
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: Light gray (RAL 9002)
Double-leaf door: hinged on the left and right
Equipment:
Tubing in the floor and ceiling: 2 each, NW 100 mm, for installing the pulsator tables
Tubing in the the side walls: 1 each, left and right, 100 mm
Cooling unit: Air-cooled
Control: Digital measurement and control system DMR
Basic control panel: Integrated into the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance data:
Temperature range without air conditioning: +20...+100 °C
Temperature stability without air conditioning: +0.2 ... t0.5 K (over time) depending on the range, in steady state
Temperature range with air conditioning: 20...+95 °C
Temperature stability with air conditioning: +0.2 ... +0.5 K (over time) depending on the range, in steady state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH depending on the range, in steady state
Temperature change rate measured in the exhaust without a test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. On average, between +20 and +100 °C
The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel construction for placing and attaching to the climatic test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for changing test specimens, 12 weights of 5 kg each
• 1 base frame in mild steel welded construction for attaching to the underside of the climatic test chamber. This frame is equipped with removable panels on all sides and has two hinged doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric discs with bearings and tachometer, 2 connecting rods, 2 ball bearings,
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for attaching the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for attaching the buttocks simulation
• 2 stainless steel 60° load rods (The connection to the test specimen is not included in our price, but can be offered subsequently upon precise specification.)
• 2 three-phase motors, 2 belt drives with tensioning devices,
• 1 pneumatic control unit with 2 manual valves, a filter-regulator unit, and a shut-off valve. 1 electrical control cabinet with 2 SEW frequency converters, hand switches, emergency stop button, 2 on/off switches, 2 speed indicators, 2 potentiometers for speed adjustment, 2 pre-selected load changers with zero position and shutdown.
Technical specifications:
Bodpfx Aasxbgrgsqeww
Frequency: 100-1000 strokes/minute
Load: 2 x 45 g
Stroke: 0-40 mm
Load from above: 450 N each
You can find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,623 km
Climate test chamber 600 liters with humidity
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: excellent (used), Weiss
Model: WK3-600/70
Climate Test Chamber, Water-cooled
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Temporal: ±0.1 to ±0.5 K
Spatial: ±0.5 to ±1.5 K
Heat compensation: max. 2500 W
Specifications for climate testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98% r.h.
Temperature deviation (temporal): ±0.1 to ±0.3 K
Temperature deviation (spatial): ±0.5 to ±1 K
Humidity deviation (temporal): ±1 to ±3% r.h.
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation: max. 500 W
Test chamber volume: 600 liters
Test chamber dimensions (H x W x D): 950 mm x 800 mm x 800 mm
External dimensions (H x W x D): 1998 mm x 1000 mm x 1745 mm
Feedthrough diameters: NW 125 mm and NW 50 mm
Operating data:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 9.1 kW
Nominal current: 19.0 A
Refrigerant: R 452A & R23
Weight: 680 kg
Important safety information for buyers!
The following procedures are carried out on all chambers we offer prior to delivery:
1. Functional check and replacement of necessary components
2. If necessary, the chamber is refilled with refrigerant in compliance with applicable laws
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Bjdpfsw Nqhpsx Aaqoww
Condition: used
Scope of delivery: (See image)
(Specifications subject to change and possible errors!)
If you have further questions, feel free to call us.
Listing
Borken
7,614 km
Weathering test device Test chamber
HeraeusXenotest 1200 CPS
Call
Operating hours: 3,888 h, condition: good (used), Heraeus Xenotest 1200 CPS weathering tester
Xenon device for testing the lightfastness and weather resistance of materials under simulated conditions
Bwjdpfx Aaexal Haeqew
Electrical connection
Voltage: 400 V
Nominal current: 50 A max.
Connected load: 33 kVA max.
Power consumption of xenon lamps: 2.8 - 6 kW per lamp
Compensation: 3 capacitors, 50 uF each
Operating hours: 3888
You can find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
7,623 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Weight: approx. 2,100 kg
Bwedpfxew I Rxro Aaqjw
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,614 km
Large-scale climate test chamber
VötschVCZ 04032
Call
Condition: good (used), Large-scale system for climate tests with S!MCON control
Design
The system consists of the following main components:
- Walk-in, insulated test room
- Air treatment room
- Machine unit
- Air conditioning system
- Control cabinet
Test room
The fixtures in the test room are made of corrosion-resistant material.
The test room can be illuminated, is walk-in, and has a condensate and cleaning drain.
Air treatment room
The air treatment room is located behind the air baffle in the insulated interior.
It contains the following components necessary for temperature control and is accessible via easily removable panels.
- Test room fans
- Heat exchangers
- Electric heaters
- Ventilation and exhaust system
- Temperature sensors
In the air treatment room, the air is tempered (cooled/heated), humidified and dehumidified, and circulated by fans.
Bwjdpfx Aow U Sv Eeaqjw
The air is drawn in under the ceiling and expelled at floor level.
Sensors
The temperature and humidity sensors are located behind the air baffle in the air treatment room.
Machine Unit
The machine unit, consisting of refrigeration units, supplies the air treatment room with the required energy.
Climate System
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Direct temperature range: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5°C
Humidity fluctuation: +/- 3 to +/- 5% RH
Cooling water specifications
Connections
Inlet: 2 x 1 1/2" RH
Return: 2 x 1 1/2" RH
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10,000 N/m²
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m, Height 2.20 m, Depth 5 m
Climate chamber divided for transport at a specified location (approx. 2.50 m).
Find more items – new and used – in our shop!
International shipping costs on request!
Listing
Borken
7,623 km
Climate test chamber 600 liters
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: good (used), Weiss
Type: WK3-600/70
Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Over time: ±0.1 to ±0.5 K
Spatially: ±0.5 to ±1.5 K
Heat compensation max.: 2,500 W
Specifications for Climate Testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98 % rH
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1 K
Humidity deviation over time: ±1 to ±3 % rH
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation max.: 500 W
Test chamber volume: 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1,998 mm, Width 1,000 mm, Depth 1,745 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19.0 A
Refrigerant: R404A & R23
Weight: 680 kg
Bsdpfx Aow Inmmjaqoww
Important information for you as the buyer:
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications subject to change. Errors and omissions excepted!)
If you have any further questions, we are happy to answer them by phone.
Listing
Borken
7,614 km
Climate test chamber
EspecPR-3KP
Call
Condition: good (used), operating hours: 75,383 h, Espec PR-3KP Environmental test chamber -20 to +100 °C
Features:
Manufacturer: Espec
Type: PR-3KP
Temperature range: -20 to +100 °C
Humidity: 20 to 98 % rH
Refrigerant R-404A:- CFC-free - ozone-friendly
Operating hours: 75383
Bjdpowbz Hhjfx Aaqjww
Dimensions:
External dimensions: HxWxD= 1680 x 1050 x 1200 mm
Chamber dimensions: HxWxD= 850 x 600 x 800 mm
Further items in other sizes - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
7,623 km
Climate test chamber -10°C to +90°C
VötschVC 0018
Call
Condition: used, Vötsch
Model: VC 0018
Climate Test Chamber, Air-Cooled
Test Chamber Dimensions: Width 580 x Depth 450 x Height 750 mm
External Dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test Chamber Volume: approx. 190 liters
Specifications for Temperature Testing:
Temperature Range: -10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.5 K
spatial: ±0.5 to ±2.0 K
Temperature Change Rate according to IEC 60068-3-5
Heating: 0.6 K/min
Cooling: 0.3 K/min
Heat compensation in the range +20°C to +50°C: 200 W
Calibration Points: +4°C and +90°C
Specifications for Climate Testing:
Temperature Range: +10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.3 K
spatial: ±0.5 to ±1.0 K
Humidity Range: 10% to 98% RH
Electrical Connection:
Rated Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 1.7 kW
Rated Current: 9.5 A (neutral conductor plug loaded), Schuko approx. connection cable: 3.5 m
Protection: 16 A slow-blow, provided by the customer
Weight: approx. 380 kg net
Refrigerant: R 134A
For your safety as a buyer, please note the following information!
The following points are carried out on all climate chambers we offer prior to delivery:
Bodpfjw Hz S Ujx Aaqjww
1. Functional check and replacement of necessary components
2. If necessary, a refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data are subject to change and errors are excepted!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Climate test chamber 1540 liters
WeissWK1-1500/40 Temp. -40°C bis +180°C
Call
Condition: used, Weiss
Type: WK1/1500/40
Weiss Climate Test Chamber, Air-Cooled with Humidity Control
(converted to use refrigerant R-452a)
Temperature range: -40°C to +180°C
Cooling rate approx. 2.5 K/min, heating rate approx. 3.5 K/min
Temporal temperature deviation at center of test space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature range: +10°C to +95°C
Humidity range: 10% to 98% r.H.
Temporal temperature deviation at center of test space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Heat compensation
In the range of +25°C to +95°C, at a relative humidity up to 90%: 500 W
Bsdpfow Hcttex Aaqsww
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 1475 mm
External dimensions: Height: 2005 mm, Width: 1300 mm, Depth: 2450 mm
Test volume: approx. 1540 liters
Test chamber lighting: Halogen bulb 12V, 50W
Rated voltage: 3/NPEAC 400V ±10% 50Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Fuse on site: 32A slow-blow
Protection class (control cabinet and operator panel): IP 54
Refrigerant: R-452a
Weight: 920 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
7,623 km
Climate test chamber with humidity, 306 liters
EspecPSL-2KPH -70°C bis +150°C
Call
Condition: excellent (used), Espec
Type: PSL-2KPH
Thermo TEC
Espec Temperature and Climate Test Chamber, Air-Cooled
Temperature range: -70°C to +150°C
Humidity range: 20 to 98% rH
Temperature/Humidity Fluctuations: ± 0.3°C / ± 2.5% rH
Temperature/Humidity Stability: ± 0.5°C / ± 3% rH
Heat-up time: from -70°C to +150°C in 50 min
Cool-down time: from +20°C to -70°C in 80 min
Test chamber dimensions: width 600 mm x height 850 mm x depth 600 mm
External dimensions: width 1010 mm x height 1690 mm x depth 1173 mm
Test chamber volume: 306 liters
Refrigerants: R-404A, R-508A
Stainless steel construction
Connection: AC 400V 3~ 50/60 Hz Max. 18 A
Rated power: 1.5 kW
Net weight approx. 400 kg
For your safety as a buyer, please note the following information!
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New charge with legally compliant refrigerant
3. After successful inspection, the chambers undergo a test run, monitored with calibrated instruments.
Condition: used
Scope of delivery: (see photo)
Bjdpfxjw D Dgvj Aaqeww
(Technical data and specifications may be subject to change and errors!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,623 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here we offer shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
Temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Bwjdpfei Az Egjx Aaqew
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Operating hours: 27.903 hrs.
Weight: 1000 kg
For you as a buyer, the following information for your safety!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Type: VT 7012 S2
Water-cooled
Two-chamber design
Hot chamber:
The temperature range of the hot chamber is from +50°C to +220°C.
Temperature deviation over time in the center of the chamber is ± 1 K.
Temperature deviation over space is ± 2 K.
Temperature change rate:
Heating: 11 K/min.
Cold chamber:
The temperature range of the cold chamber is from -80°C to +70°C.
Temperature deviation over time in the center of the chamber is ± 1 K.
Bodpfjwzilrox Aaqoww
Temperature deviation over space is ± 2 K.
Temperature change rate:
Heating: 2 K/min.
Cooling: 3 K/min.
Test chamber volume: 125 liters.
Hot chamber temperature range: +50°C to +220°C.
Cold chamber temperature range: -80°C to +70°C.
Test chamber dimensions: Width: 470 mm. Depth 650mm Height 410mm
External dimensions: Width 930mm Depth 2115mm Height 1970+mm
Plug-in diameter 67mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power 10 kW
Rated current 25 A
Refrigerant R404A / R23
Weight: 1000 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-10 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-10
Vötsch Climate Test Chamber, Water-cooled
Specifications for Temperature Testing:
- Temperature range: -70°C to +180°C
- Temporal temperature deviation at the center of the usable test volume: ±0.3 to ±0.8 K
- Spatial temperature deviation: ±0.5 to ±2 K
- Temperature gradient: 1 to 4 K
- Temperature change rate:
- Heating: 11 K/min
- Cooling: 10.5 K/min
Specifications for Climatic Testing:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98% RH
- Temporal temperature deviation at the center of the usable test volume: ±0.2 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temperature gradient: 1 to 2 K
- Temporal humidity fluctuation at the center of the usable test volume: ±1 to ±3 % RH
Technical Data:
- External dimensions (with hinges and door lock):
- Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
- External dimensions (without hinges and door lock):
- Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
- Internal chamber dimensions:
- Height: 950 mm, Width: 1100 mm, Depth: 950 mm
- Test chamber volume: approx. 1300 liters
Feedthroughs:
- The chamber is equipped with feedthroughs on both the right and left sides, allowing measurement cables and test devices to be routed into the test space.
- 1 x R1 NW 125 mm
- 1 x L1 NW 50 mm
Test Chamber Lighting:
- Halogen bulb 24 V, 50 W
Electrical specifications:
- 3/N/PE AC 400V ±10% 50Hz
- Rated power: 34.0 kW
- Rated current: 50.0 A
- Fuse (to be provided on site): 100 A slow-blow
- Max. heat emission to environment: 2.2 kW
Permissible Test Specimen Weight:
- Total load on grate supports: 100 kg
- Chamber floor: 150 kg; Inserted rack: 50 kg
Refrigerants:
- R 404A / R 23
Weight: 1600 kg
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Bedpfxswynmxo Aaqjww
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in technical data and information!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,623 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
Bedpfswxc I Uex Aaqeww
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Germany
7,623 km
Stress test chamber
EspecEHS-221M
Call
Condition: excellent (used), Espec
Here we offer an Espec(ThermoTec) stress test chamber.
Overpressure humidity tests at over 100 degrees in many different modes
Program capacity of 10 patterns with 30
steps per pattern
A variety of protection mechanisms; overheat/overpressure protection, detection of water-
supply failure.Complete door interlock and temperature sensor.
Saturated Temp Range 105 to 142.9°C
Unsaturated Temp Range 105 to 132.9°C
Humidity range 50 to 100% r.h.
Nominal pressure 0.196 MPa at 132.9°C and 100% e.F.
External dimensions: width 740 x height 1553 x depth 1000 mm
Test chamber dimensions: Width 355x Height 355 x Depth 426 mm
Other equipment:
with rails and grid
Test material connections in the interior
Type: EHS-221M
Scope of delivery: See pictures
300 kg
Condition: Used
Scope of delivery: (See picture)
Bsdpon Arznjfx Aaqsww
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Stress test chamber
EspecEHS-221MD
Call
Condition: excellent (used), Espec
Here we offer an Espec (ThermoTec) stress test chamber.
Outer dimensions: W x H x D: 860 x 1795 x 1000 mm
Bwjdpfxopdm Uyj Aaqsw
Test chamber dimensions W x H x D: 355 x 355 x 426 mm
2 x 46 l
Voltage 230 V 1/N 50 Hz
Rated current 37A
Fuses 250 V , 2 x 3 A
Type: EHS-221MD
Temperature range: + 105°C to + 142.9°C
Humidity range 75 to 100 % r.H.
Temperature constancy: -+ 0.5 °C
Pressure range: 0 to 2.0 kg/cm²
Heat-up or pressure build-up time: from 0 to 2.0 kg/cm² in about 60 minutes
390 kg
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Temperature chamber with vibration table
EspecQualmark T2.5 + Kompressor 99480630
Call
Condition: like new (used), HALT/ HASS Espec
Bwjdpfx Aoqwybgeaqow
Here we offer you a temperature chamber.
Temperature -100 to + 200°C
Table in lower position (WxDxH) 889 x 889 x 889 mm
Table in upper position (WxDxH) 889 x 889 x 635 mm
Overall dimensions (WxDxH) 1425 x 1748 x 2134 mm
Work table 762 x 762 mm
Max load 145 kg
Acceleration 5 to 75 gRMS
Voltage
480 or 440 V / 60 A / 3F
400 or 380 V / 80 A / 3F
Type: Qualmark T2.5 + compressor 99480630
Condition: used Only 147 hours
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,623 km
Temperature chamber 986 liters
ThermotronSE-1000-6-6 -70°C bis + 180°C
Call
Condition: excellent (used), Here we offer you Thermotron temperature chamber.
Water cooled
Thermotron temperature chamber SE-1000-6-6
Inner dimensions: WxDxH 1000 x 1000 x 980 mm
Working volume: approx. 980 liters
Temperature range: -70ºC to 180ºC
Heating up total : ca 4,1 K
Cooling down total : ca 1,2 K
Heating power in ºC/minute -65º to 71ºC: 6.8ºC
Heating power in ºC/minute -65º to 180ºC: 5.6ºC
Heating capacity in ºC/minute -40º to 85ºC: 6.5ºC
Cooling capacity in ºC/minute 85º to -40ºC: 4.7ºC
Cooling capacity in ºC/minute 71º to -65ºC: 3.7ºC
Cooling capacity in ºC/minute 180º to -65ºC: 4.3ºC
External dimensions - WxDxH: 1250 x 1900 x 2200 mm
Electrical requirements 400V/5P/N/PE 35 A
Refrigerants: R508B and R404 A
Bwedpfeixtitex Aaqsw
Approx. weight: 900 kg
Type: Thermotron SE- 1000-6-6
For you as a buyer, the following information for your safety!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Bwsdpfx Aasuudx Deqow
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature chamber 2000 liters
CTST-40/2000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Refrigeration unit:
air-cooled, low-noise, fully hermetic, infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door hinge left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per shelf 35 kg
Total load with max. grid load 100 kg
Test area lighting: 3x halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature range: -40°C to +180°C
Nominal voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Nominal current: 17.2 A
Compressor: TFH2516Z
Pipe feed-through NW 50
Control panel
Bedpfxoup T Uqj Aaqjww
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, width 975, depth 2200 mm
External dimensions: Height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1 m from the front) < 55 dB(A)
Weight: approx. 1200 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature chamber
WEISSWT11-1000/70/5
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer a Weiss temperature chamber.
Weiss temperature chamber air cooled with Weiss condenser cooler
Test chamber capacity approx. 990 liters
Data for temperature tests:
Temperature range -70°C to +180°C
Temperature deviation in time in the center of the chamber ± 0.1 to ± 0.5 K
Temperature deviation spatially ± 0.5 to ± 2.0 K
Temperature gradient (acc. to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 5 K/min
Bedpfx Aasp Dun Aeqoww
Cooling 5 K/min
Heat compensation max. 2750 W
Feedthrough built into basic equipment
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x depth 950 mm x height 950 mm
Housing dimensions: width 1390 mm x depth 1525 mm x height 1995 mm
maximum load (evenly distributed over the surface) of the test chamber floor 150 kg
per insert grate 50 kg
total load of the grate supports 100 kg
Data for operation:
Test room lighting halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 27,0 kW
Rated current 42,02 A
Heat output water-cooled test chambers max. heat output to environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: ( converted to R-452a )
weight: approx. 960 kg
Type: WT11-1000/70/5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. function check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
We make it easier for you to find: "temperature test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Temperature Test Chamber (17,509)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
- Climate Chamber
- Climatic Test Chamber
- Cold Rooms
- Cooling Room
- Drying Chamber
- Electronics Tester
- Engine Test Bench
- Feutron Climate Chamber
- Glass Chamber
This may be of interest to you















































































































































































































































