Used Temperature Test Chamber for sale (16,970)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Here we offer Vötsch shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
Gbjdpfxoigg Hno Afnoh
cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here we offer shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
Temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Gjdei Az Egepfx Afnjbh
Operating hours: 27.903 hrs.
Weight: 1000 kg
For you as a buyer, the following information for your safety!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Temperature chamber for AllroundLine
Zwick / RoellEC76G 1-1-2-0 361763 -80°C bis + 250°C
Call
Condition: as good as new (ex-display), Year of construction: 2018, Zwick / Roell
Type: EC76G 1-1-2-0 361763
Description:
Zwick / SFL Severn Furnaces Limited
Zwick/Roell temperature chambers for tests in the temperature range - 80°C to + 250°C
Traceable test results and perfect integration of the temperature chamber into the test system.
Gbjdpfx Aslguwwjfnsh
Temperature control chambers: width 600 mm x height 1000 mm
Temperature control chamber for the AllroundLine
Cooling using LN2 (liquid nitrogen)
(-80°C external connection, not included)
Voltage: 400/230 16A 3N〜50/60Hz
Power: 4500W
Weight: 180 kg
Condition: unused
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,623 km
Environmental test chamber -70°C - +180°C Humidity
ThermotronSM-8-8200
Call
Condition: excellent (used), Here we offer you Thermotron environmental test chamber.
Thermotron Environmental Test Chamber Water Cooled
Working volume: 227 liters
Temperature uniformity: All models 0.7°C
Temperature range: -70°C to + 180°C
Temperature control tolerance: All models 0.3°C
Shipping weight: approx 400 kg
Internal dimensions width 610 mm x depth 610 mm x height 610 mm
Outer dimensions width 890 mm x depth 1240 mm x height 1850 mm
Humidity range: All models 10% to 98% RH
Humidity control: All models 2.5% RH
Heating capacity in minutes -65º to 71ºC: 17
Heating power in minutes -65º to 180ºC: 43
Heating power in minutes -40º to 85ºC: 16
Electrical requirements in full load amplifiers 230/3/60: 19
Electrical requirements in full load amplifiers 230/1/60: 25
Electrical requirements in full power amplifiers 220/1/50: 27
Cooling capacity in minutes 85º to -40ºC: 32
Cooling capacity in minutes 71º to -65ºC: 54
Cooling capacity in minutes 180º to -65ºC: 72
Compressor size: (2) -2 Hp
Operating voltage: 400V 16.7 A
Type: SM-8-8200
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Godpfx Afomhfr Ienobh
Listing
Germany
7,623 km
Chamber for parametric testing
S & A4365A
Call
Condition: excellent (used), S & A Test Chamber
Here we offer you a S & A test chamber for parametric testing.
Temperature range
-55 ° C to 200 ° C (LCO2)
-65 ° C to 200 ° C (LN2)
Temperature change rate
15° C / min (Standard Option)
60° C / min (Fast Option)
Gbjdpfx Aen Arl Sefnjh
Stability
± 0.2 ° C (including effects of mains voltage, ambient temperature
between 15° and 45° C and aging)
Uniformity
± 1.0 ° C Max from -65 ° C to -55 ° C
± 0.5 ° C Max from -55 ° C to + 125 ° C
± 1,0 ° C Max from + 125 ° C to + 200 º C
Coolant: LCO2
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 61 kg
Type: 4365A
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Discover more used machines
Listing
Borken
7,623 km
Climate test chamber with humidity 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Weiss climate test chamber water-cooled
(refrigerant converted to R-452A)
Temperature test
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Minimum temperature -42°C
Maximum temperature +180°C
Temperature change rate, cooling 4 K/min
Temperature change rate, heating 3.2 K/min
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ±1.5 K
Climate test:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ±1 K
Humidity deviation, temporal ± 1 to ± 3 % r.h.
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Type: WK3-340/40
Weight Approx. 515 kg
Gbjdpjq U Sdcjfx Afnjh
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate test chamber with humidity 800 liters
EspecEGNX28-6CWL -70 bis +180°C
Call
Condition: excellent (used), Espec
Type: EGNX28-6CWL
Espec climate test chamber water-cooled
Climate test chamber N series
Temperature range -70 to +180°C
Temperature change rate
Heating 10 °K/min
Cooling 5.5 °K/min
Humidity range 10 to 95% RH according to diagram
Internal dimensions W x H x D in mm 1000 x 1000 x 800
External dimensions W x H x D in mm 1205 x 1930 x 1960
Usable space volume 800 liters
Cooling capacity 3.6 kW at -50 °C
Heating system 10 kW
Refrigerant R-404A
Gbedpfsv Duuxox Afnoh
Refrigerant R- 508A
Power supply:
AC 400 V 3-phase 50/60Hz 38A
Weight: approx. 695 kg
For your safety as a buyer, the following information!
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature shock chamber 200 liters
EspecTSA-202E-W -55°C bis 200°C
Call
Condition: excellent (used), Espec
Type: TSA-202E-W
Temperature Shock Chamber, Water-Cooled
Cold Chamber: -55°C to 0°C
Hot Chamber: +50°C to 200°C
System: Two-zone test with damper control
Temperature fluctuation ±0.5°C
Hot Chamber:
Temperature heating time: Ambient temperature (20°C) to +200°C within 15 minutes.
Cold Chamber:
Temperature reduction time: Ambient temperature (20°C) (20°C) to -55°C within 35 minutes.
Temperature recovery: within 5 minutes.
Internal dimensions (W x H x D mm): 650 x 460 x 670
External dimensions (W x H x D mm): 1550 x 1900 x 1670
Approx. 200 liters
Power supply: 400 V AC 50Hz: 65 A
Refrigerant: R404A 5 kg R23 2.0 kg
Weight: Approx. 1200 kg
For your safety as a buyer, please note the following:
Godpfxjwc R A Ie Afnjbh
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Temperature Test Data:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Climate Test Data:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at center of workspace: ±1 to ±3% RH
Maximum heat compensation: 8000 W
Enclosure dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Gbedpfswvgwbsx Afnoh
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides. These allow for test leads and testing devices to be routed into the chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber illumination:
Halogen bulb 24V, 50W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Customer-provided fuse: 100 A slow-blow
Maximum heat output to the environment: 2.2 kW
Permissible test item weight:
Total load on shelf supports: 100 kg
Test chamber floor: 150 kg, Removable shelf: 50 kg
Refrigerants: R 404A/R 23
Weight: 1900 kg
For your security as a buyer, please note:
The following steps are carried out in advance on our chambers offered for sale:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer any further questions by phone.
Listing
Borken
7,623 km
Climate test chamber 1540 liters
WeissWK1-1500/40 Temp. -40°C bis +180°C
Call
Condition: used, Weiss
Type: WK1/1500/40
Weiss Climate Test Chamber, Air-Cooled with Humidity Control
(converted to use refrigerant R-452a)
Temperature range: -40°C to +180°C
Cooling rate approx. 2.5 K/min, heating rate approx. 3.5 K/min
Temporal temperature deviation at center of test space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature range: +10°C to +95°C
Humidity range: 10% to 98% r.H.
Temporal temperature deviation at center of test space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Heat compensation
In the range of +25°C to +95°C, at a relative humidity up to 90%: 500 W
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 1475 mm
External dimensions: Height: 2005 mm, Width: 1300 mm, Depth: 2450 mm
Test volume: approx. 1540 liters
Test chamber lighting: Halogen bulb 12V, 50W
Rated voltage: 3/NPEAC 400V ±10% 50Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Fuse on site: 32A slow-blow
Protection class (control cabinet and operator panel): IP 54
Refrigerant: R-452a
Weight: 920 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
Gbodpjw Hcttefx Afnsh
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
7,623 km
Climate test chamber with solar simulation
Atlas / WeissSolarClimatic SC-340
Call
Condition: excellent (used), Atlas
Type: SC 350 MHG
Atlas Solar Climatic Test Chamber, Air-Cooled
For sale is an ATLAS SC-340 MHG SolarClimatic Test Chamber
(climatic chamber with solar simulation via MHG lamp).
Gedpfx Aexbd Rajfnebh
The device is suitable for carrying out standardized weathering and aging tests under the combined influence of radiation, temperature, and climate.
Features & Highlights:
- Precise temperature and humidity control
- Integrated humidification system with water reservoir
- Cooling via water or air system (optional)
- Feed-throughs available for measuring leads
- Control via control panel or interfaces (RS232, etc.)
- Sturdy test chamber floor, loadable up to 60 kg (optionally reinforced to 150 kg)
General Data:
Model: SC 340 MHG
Test chamber volume: approx. 335 liters
Cabinet weight: approx. 500 kg
Irradiation unit weight: approx. 65 kg
Technical Data:
Test volume: 340 l (internal dimensions 580 × 765 × 750 mm)
External dimensions (W×D×H): 865 × 1,595 × 2,180 mm
Light source: 1 × 1,200 W MHG lamp
Irradiance: 800–1,200 W/m²
Illuminated area: approx. 3,300 cm²
Weathering spectrum: 300–3,000 nm, compliant tests according to DIN 75220, IEC 60068-2-5, MIL-STD-810F
Temperature range with irradiation: –20 °C to +100 °C (±1 K)
Temperature range without irradiation: –30 °C to +100 °C (±0.1–0.5 K)
Heating/Cooling rates: 3.0 K/min (heating), 2.5 K/min (cooling, without irradiation)
Noise level: approx. 58 dB(A) at a distance of 1 m
Power supply: 400 V, 3/N/PE, 50 Hz
Power consumption: max. 6.2 kW, 16 A
Refrigerant: R-404A
Weight: approx. 565 kg
Information for your safety as a buyer!
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers are subjected to a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical details subject to change and errors reserved!)
Feel free to contact us by phone for any further questions.
Listing
Borken
7,623 km
Temperature chamber
WEISSWT1-340/30
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer Weiss temperature chamber.
Converted to R452a
Weiss temperature chamber air cooled
Temperature range: from - 30°C to 180°C
Gbsdpfx Asic Rgfofnoh
Temperature change rate cooling 1,6 K/min
Temperature change rate heating 2,1 K/min
Test chamber dimensions: Width 550 mm x depth 750 mm x height 800 mm
Housing dimensions: Width 800 mm x depth 1500 mm x heights 1800 mm
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4,9 kW Rated current 9 A
Refrigerant: R452a
Weight: 515 kg
Type: WT1-340/30
For you as a buyer the following information for safety!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Shock test chamber +50 - 220°C -80 - +70°C
VötschVT 7012 S2 (6603)
Call
Condition: excellent (used), Here we offer Vötsch shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Gbjdpfx Ajn Arc Ajfnoh
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions Width 470 mm Depth 650 mm Height 410 mm
External dimensions Width 930 mm Depth 2115 mm Height 1970 mm
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V ±10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climatic test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), Here we offer a Weiss climatic test chamber.
Water-cooled
Test chamber lighting Halogen bulb 24V, 50W
Data for temperature tests:
Temperature range: -40°C to +180°C
Temporal temperature deviation in the center of the chamber: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 10 K/min
Cooling: 12.5 K/min
Heat compensation at +20°C 8000 W
Gjdpfx Asq Dpzyofnjbh
Heat compensation at -20°C 3000 W
Data for climate tests
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH
Test chamber dimensions: Height 950 mm, width 760 mm, depth 650 mm,
External dimensions: Height 2025 mm, width 1090 mm, depth 2480 mm,
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Rated current: 24 A Rated power: 16.0 KW
Refrigerant: R452A
Weight: approx. 900 kg
Type: WK-480/40/10
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/1000
CTS climatic test chamber
Condenser chiller air-cooled
Control:
32 bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature test:
Temperature range: -40°C to +180°C
Temperature change rate
Heating speed 2.0 K/min
Cooling rate 2.5 K/min
Temperature deviation ± 0.1 to ± 0.3 K in time
Heat radiation:
approx. 2500 W at +20°C
approx. 2500 W at ± 0°C
approx. 1500 W at -20°C
Climate Working range:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Dew point range I +7 to +94°C
Dew point range II -10 to +7°C
Temperature deviation ± 0.1 to ± 0.3 K in time
Humidity constancy I, temporal ± 0.5 to ± 1.5 % r.h.
Humidity constancy II, temporal ± 1 to ± 3 % r.h.
Panorama window 570 x 710 mm
Test chamber dimensions Width 1000 mm Depth 1100 mm Height 900 mm
External dimensions Width 1270 mm Depth 2220 mm Height 1950 mm
Test chamber volume 1000 liters
Pipe feed-throughs, ø 50
Electrical connection: 400 V +6/-10% 3/N, PE 50 Hz
Connected load: 8.4 kW Rated current: 12.4 A
Refrigerant: R-404A
Weight: 800 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Gedjru Dzujpfx Afnebh
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature shock test system
RS-SimulatorenST2K320/45 K
Call
Condition: excellent (used), RS. simulators
Type: ST2K320/45 K
Water-cooled shock test system
Temperatures in the upper test chamber
Temperature range: + 40 °C to + 180 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Temperatures in the lower test chamber
Temperature range: - 40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Humidity in the upper test room
Climatic temperature range: + 40 °C to +90 °C
Humidity range: 20 % to 98 % (± 2 to 5 %) relative humidity
Humidity: 25% to 75% relative humidity
Working climate range:
Temperature: + 12 °C to + 30 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 900 mm Height 2000 mm Depth 2300 mm
Test room dimensions: Width 470 mm Depth 700 mm Height 440 mm
Electrical power supply:
Total power: 13 KVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
The following information is for your safety as a buyer!
Gjdpfxotrf Ule Afnebh
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test cell Walk-in test system
CTSTW-60/9 -60°C bis +100°C 9m³
Call
Condition: excellent (used), CTS
Type: TW -60/9
Temperature test cell water-cooled
CTS temperature test cell type TW -60/9
T means: Temperature
W means: Walk in
-60 means: lower temperature -60°C
9 means: 9 m³ test chamber volume
Technical design:
Refrigeration unit:
water-cooled, low-noise, semi-hermetic,
infinitely variable capacity adjustment by electronic
monitoring and control system,
environmentally friendly refrigerant R23 / R404 A
Control system:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material
control
Technical performance data:
Temperature tests:
Temperature range -60 °C to +100 °C
Temperature deviation
± 0.1 to 0.5 K in time
Average rate of temperature change with test material and
with heat radiation measured in the supply air.
Heating: 1.6 K/min from -40 °C to +85 °C
Cooling: 1.6 K/min from +85°C to -40°C
Test material 420 kg of solar cell modules with100% flow
Heat radiation 3000 Watt permanent
The technical data refer to an ambient temperature of +25 °C, nominal voltage 400
V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 9 m³
External dimensions: Width approx. 4140 mm, depth 2680 mm, height 3000 mm
Test chamber dimensions: Width approx. 1600 mm depth 2400 mm, height 2200 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, PE, 50 Hz
Rated power 48.9 kW Rated current: 74.9 A
Gsdpfsvb E Uqjx Afnjbh
Protection class IP 54
Cooling water connections Cooling water supply/return R1 ¼"", internal thread
Unpressurized condensate drain R1" internal thread
Weight: approx. 5609 kg
Condition: used / second-hand
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test cell Walk-in test system
CTSTW-60/9 -60°C bis +100°C 9m³
Call
Condition: excellent (used), CTS
Type: TW -60/9
Temperature test cell water-cooled
CTS temperature test cell type TW -60/9
T means: Temperature
W means: Walk in
-60 means: lower temperature -60°C
9 means: 9 m³ test chamber volume
Technical design:
Refrigeration unit:
water-cooled, low-noise, semi-hermetic,
infinitely variable capacity adjustment by electronic
monitoring and control system,
environmentally friendly refrigerant R23 / R404 A
Control system:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material
control
Technical performance data:
Temperature tests:
Temperature range -60 °C to +100 °C
Temperature deviation
± 0.1 to 0.5 K in time
Average rate of temperature change with test material and
with heat radiation measured in the supply air.
Heating: 1.6 K/min from -40 °C to +85 °C
Cooling: 1.6 K/min from +85°C to -40°C
Test material 420 kg of solar cell modules with100% flow
Heat radiation 3000 Watt permanent
The technical data refer to an ambient temperature of +25 °C, nominal voltage 400
V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 9 m³
External dimensions: Width approx. 4140 mm, depth 2680 mm, height 3000 mm
Test chamber dimensions: Width approx. 1600 mm depth 2400 mm, height 2200 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, PE, 50 Hz
Rated power 48.9 kW Rated current: 74.9 A
Protection class IP 54
Cooling water connections Cooling water supply/return R1 ¼"", internal thread
Unpressurized condensate drain R1" internal thread
Weight: approx. 5609 kg
Condition: used / second-hand
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Gbjdpfx Afjvb Hanenoh
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate test chamber with humidity
Weiss -72°C bis +180°CWK3-340/70
Call
Condition: excellent (used), Weiss
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Gbedpsv Sr Hzofx Afnjh
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate test chamber 600 liters
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: good (used), Weiss
Type: WK3-600/70
Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Over time: ±0.1 to ±0.5 K
Spatially: ±0.5 to ±1.5 K
Heat compensation max.: 2,500 W
Specifications for Climate Testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98 % rH
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1 K
Humidity deviation over time: ±1 to ±3 % rH
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation max.: 500 W
Test chamber volume: 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1,998 mm, Width 1,000 mm, Depth 1,745 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19.0 A
Refrigerant: R404A & R23
Gjdpfx Afjw Inmmonobh
Weight: 680 kg
Important information for you as the buyer:
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications subject to change. Errors and omissions excepted!)
If you have any further questions, we are happy to answer them by phone.
Listing
Borken
7,623 km
Climatic test chamber with humidity, 600 liters
CTSC-40/600 -40 bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber Type: C -40/600, Air-Cooled
(converted to R-452a refrigerant)
Test chamber volume: 600 liters
Temperature tests:
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K over time (at stabilized condition)
- Average temperature rate of change (without test load and radiant heat):
- Heating: 2.5 K/min
- Cooling: 3.0 K/min
- Maximum radiant heat input: 2500 W at +20°C
Gbsdow U Awmjpfx Afnsh
Climatic tests:
- Climate range / Technical data:
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
- Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
- Humidity consistency II: ±1% r.h. to ±3% r.h.
- Temperature consistency: ±0.1 K to ±0.3 K
Chamber internal dimensions (approx.): Height: 850 mm, Width: 850 mm, Depth: 830 mm
External dimensions (approx.): Height: 1900 mm, Width: 1115 mm, Depth: 1850 mm
Refrigerant: R-452A
Power connection: 400V 3/N 50Hz
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for your purchase!
The following checks and procedures are performed on all our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in the technical data and specifications!)
If you have further questions, we will be happy to answer them by phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,623 km
Climate test chamber 990 liters
Weiss – 40…+ 180°CWK11-1000/40 mit Zander K-MT 2
Call
Condition: excellent (used), Weiss
Model: WK11-1000/40
For sale is a professional Weiss Umwelttechnik WT-WK 1000/40 climate test chamber with fully automatic cold-regenerating adsorption dryer.
The installed fixtures in the test chamber can be removed if required. Currently, due to these fixtures, the control cabinet is limited to a temperature range of −40°C to +60°C. Once the fixtures are removed, the manufacturer can expand the temperature range back to the standard values of −40°C to +180°C, as the fixtures are not suitable for these higher temperatures.
This equipment is ideal for precise temperature and humidity testing on components, assemblies, and devices. It is perfectly suited for applications in industry, development, quality assurance, and research.
Weiss Climate Test Chamber – Water Cooled
Data for Temperature Tests:
- Temperature range: −40°C to +60°C
- Temporal temperature fluctuation (at center of usable space): ± 0.1 to ± 0.5 K
- Spatial temperature deviation: ± 0.5 to ± 2.0 K
- Temperature change rate:
- Heating: 4 K/min
- Cooling: 3 K/min
Data for Climate Tests:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98 % r. H.
- Temporal temperature fluctuation (at center): ± 0.1 to ± 0.3 K
- Spatial temperature deviation: ± 0.5 to ± 1 K
- Temporal humidity fluctuation (at center): ± 1 to ± 3 % r. H.
- Thermal compensation:
- In the range of +25°C to +95°C
- At a relative humidity of up to 90%, 500 W
Humidification System Data:
- Reservoir volume: 20 l
- Water quality: demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 μS/cm³
- Water consumption at constant +40°C, 92% r. H.: 21/24 h
- Temperature gradient:
- (according to IEC 60068-3-5): 1 to 2 K
Test Chamber Dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External Dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Test Chamber Volume: approx. 990 liters
Gbedsx Hxkzjpfx Afneh
Nominal Voltage: 3/N / PE AC 400 V +10% 50 Hz
Nominal Power: 11.5 kW, Nominal Current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
Important information for your safety as a buyer!
The following steps are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Technical data subject to modifications and errors!)
Further questions can be answered via telephone.
Listing
Borken
7,623 km
Shock test chamber –75°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Gbjdpfjx Hhfhex Afneh
Model: VT 7012 S2
Water-cooled
Two-chamber configuration
Hot chamber:
Temperature range of hot chamber: +50°C to +220°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature range of cold chamber: -74.5°C to +70°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Port diameter: 67 mm
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerants: R-452A / R-23
Weight: 1000 kg
Important safety information for buyers:
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
We are happy to answer further questions by phone.
Listing
Borken
7,623 km
Climate test chamber 190 liters
VötschVC³ 7018 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 7018
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Gjdjx Hg Uujpfx Afnjbh
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Humidity Range: 10% to 98% RH F.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Type: VT 7012 S2
Water-cooled
Hot Chamber:
Temperature control range of the hot chamber: +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
Temperature control range of the cold chamber: -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Port ∅ 67 mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerant: R404A / R23
Weight: 1000 kg
Important information for your security as a buyer!
The following work is carried out on our listed chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
Gedpfx Aex E Tkaofnebh
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
Should you have further questions, we will be happy to answer them by phone.
We make it easier for you to find: "temperature test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Temperature Test Chamber (16,970)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month